5. Use either the up or down arrows to display the correct size outdoor
unit. Touch save to continue.
NOTE - If the defaults are correct, you do not have to make any changes, but
you must touch save. When all red text is gone, the back button will appear;
touch it to return to the "Add or Remove Non-communicating equipment?"
screen.
ADDING A HUMIDIFIER
Before adding a humidifier, be sure that the:
Humidifier is wired to the furnace or air handler control as shown on the
Optional Accessories wiring diagram (see page 42),
Entire system is wired, powered up, and the thermostat has detected
the system's installed communicating devices, and you are at the "Add
or Remove Non-communicating equipment?" screen.
To add (or remove) a humidifier:
1.
Touch the yes button on this screen.
2.
In the "non-communicating device list" screen, use the arrows to
highlight Humidifier (note the current value, Not Installed) and touch
edit.
3.
Touch one of the radio buttons to select the type of humidifier (or select
Not Installed, if removing humidifier); touch save.
4.
The previous screen returns, but the current value now shows your
selection. Touch the back button.
5.
The "Add or Remove..." screen reappears with your addition shown in
the system devices list. At this point, you may add more equipment
(touch yes) or if finished, touch the next button to advance to the
"Adjust a setting..." screen (see page 15).
NOTE - Adding humidity regulating non-communicating devices may be a
2-step procedure:
First the device must be installed and wired. After the humidifier is
installed, the setting under the "System" mode "Humidification Control
Mode" defaults to "Basic".
Second, if you want another mode, i.e. Precision, Basic Dew Point,
or Precision Dew Point, the device requires further configuration (see
page 15).
®
ADDING HUMIDITROL
Before adding a dehumidifier, be sure that:
the dehumidifier is wired to the furnace or air handler control as shown
on the Optional Accessories wiring diagram (see page 42),
the entire system is wired, powered up, and the thermostat has
detected the system's installed communicating devices, and you are
at the "Add or Remove Non-communicating equipment?" screen.
To add (or remove) a dehumidifier, you must be at the "Add or Remove
Non-communicating equipment?" screen.
1.
Touch the yes button on this screen.
2.
In the "non-communicating device list" screen, use the arrows to
highlight Dehumidifier and touch edit. Note the current value (e.g. Not
Installed).
3.
Touch one of the radio buttons to select the type of dehumidifier (or
select Not Installed, if removing dehumidifier); touch save.
4.
When you scroll to the Dehumidifier device, (Note the current value,
e.g. Humiditrol.) Click back to return to the "Add or Remove..." screen.
5.
The "Add or Remove..." screen reappears with your addition shown in
the system devices list. At this point, you may add more equipment
(touch yes) or if finished, touch the next button to advance to the
"Adjust a setting..." screen.
NOTE - Adding humidity regulating non-communicating devices may be a
2-step procedure:
First the device must be installed and wired. After the dehumidifier is
installed, the setting under the "System" mode "Dehumidification
Control Mode" defaults to "Basic".
Second, set Humiditrol
dehumidification setpoints if desired (see page 16).
®