Specifications - Jøtul GF 500 DV IPI Installation And Operation Instructions Manual

Portland direct vent gas stove
Table of Contents

Advertisement

139636_02 GF 500 DV IPI January 2015
GF 500 DV IPI

Specifications

Input Rates
Natural Gas
40,000 BTU/hr. maximum input
12,800 BTU/hr. minimum input
Propane
39,500 BTU/hr. maximum input
14,000 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas:
5.0 WC (1.25 kPa)
Propane:
12.0 WC (3.0 kPa)
Manifold Pressure:
MIN
Natural Gas:
1.1 WC (.27 kPa)
Propane:
2.9 WC (.72 kPa)
f i r e - p a r t s . c o m
Figure 1. Dimensioned views, GF 500 DV IPI
4
MAX
7.0 WC (1.74 kPa)
14.0 WC (3.48 kPa)
MAX
3.80 WC (.95 kPa)
11.0 WC (2.74 kPa)
Safety Screen Barrier
FAMILIARIZE YOURSELF WITH THE VENTING,
CLEARANCE AND OTHER INSTALLATION
REQUIREMENTS IN THIS MANUAL BEFORE BEGINNING
THE INSTALLATION.
• SIT Proflame 2 Intermitent Pilot Ignition - 120V / 60 Hz
• Steady State Efficiency: 74.26% NG / 73.92% LP
• AFUE Efficiency:
67.3% NG / 67.1 % LP
• CSA P4. 1-02 Fireplace Efficiency:
NG - 76.2%
LP - 77.1%
• Factory Air Shutter Settings: NG - 1/16" LP - 1/8"
• Continuous Pilot Ignition Mode (CPI) is available
• Power Requirement: 120 VAC
Back-up Battery Pack: 4, AA - 1.5V
• Ambient Temperature Range: 32 -122°F (0 - 50°C)
Height Dimensions with Optional Short Legs:
- subtract 2 1/4 in. (57 mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf 500 dv

Table of Contents