Quiet Function Setting - Daikin RY24PEV1K Service Manual

Duct type
Table of Contents

Advertisement

3.4.13 Quiet Function Setting

Quiet function consists of two kinds: quiet and auto quiet.
Press Function button till the unit enters quiet function setting state, Quiet or Auto Quiet
mark blinks. In this case, press ▲ or ▼ button to switch between Quiet and Auto Quiet
and then press Enter/Cancel button to turn on this function.
In quiet mode, press Function button till the unit enters quiet function. In this case, Quiet
or Auto Quiet icon blinks and then press Enter/Cancel button to cancel this function.
Quiet function setting is shown in Fig.3.4.13
Note:
1. During quiet function, fan speed is un-adjustable.
2. When turning on auto quiet function, the unit will enter quiet running state according to
3. In auto quiet mode, fan speed can not be raised but reduced. If high fan speed is
4. There is not auto quiet function in fan or dry mode. Quiet off is default after power
5. If quite function is set, turbo function will be canceled.
53
temperature difference between room temperature and setting temperature. In this
case, fan speed is adjustable. If temperature difference between room temperature
and setting temperature ≥ 4°C, fan will keep its current speed; if 2°C ≤ temperature
difference ≤ 3°C; fan speed will be reduce one grade ,but if it is at min. grade, it is
un-adjustable.; if temperature difference ≤ 1°C, fan speed will be at min. grade
manually adjusted, auto quiet mode will quit.
failure and then power recovery.
Fig.3.4.13 Quiet function setting
SiK401004_A
FUNCTION CONTROL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents