12. Select [5 Sentence].
35° 45. 6789'N
13. Press the cursorpad to select the sentence then press the NU/CU ENT key.
14. Press the cursorpad (
TX interval: [---], [0.1s]*, [0.2s]*, [1s], [2s], [3s], [4s], [5s], [6s], [10s], [15s], [20s],
[30s], [60s], [90s]
*: Only for GGA, GLL, GNS, RMC and VTG when selecting [38400 bps] at step 11.
Note 1: Keep the "Load Rate" below 100% when setting the TX interval. The TX
interval for other than the ZDA sentence cannot be guaranteed if the rate exceeds
100%.
Note 2: For the TX interval of [0.1s] or [0.2s], set the positioning cycle (Refer to
the Operator's Manual) as follows:
• For [0.1s], set the positioning cycle at 10Hz.
• For [0.2s], set the positioning cycle at 5Hz or 10Hz.
15. Press the NU/CU ENT key.
16. Set [2 Output Data2], [3 Output Data3] and [4 Output Data4] as well.
17. Press the MENU/ESC key to close the main menu.
135° 45. 6789'E
or
) to select the TX interval.
3. ADJUSTMENTS
3-15