Flush Mounting, Fixed At Front; Flush Mounting, Fixed At Rear - Furuno GP-170 Installation Manual

Hide thumbs Also See for GP-170:
Table of Contents

Advertisement

1. MOUNTING
1.1.2

Flush mounting, fixed at front

An optional flush mount kit type F is required. For details, see the outline drawing at
end of this manual. (Name: Flush Mount Kit F, Type: OP20-41, Code No.:001-243-
900)
Name
Self-tapping screw 5×20 SUS304
Hex.bolt
Spring washer
Cosmetic panel
1.1.3

Flush mounting, fixed at rear

An optional flush mount kit type S is required. (Name: Flush Mount Kit S, Type: OP20-
40, Code No.: 001-243-890)
Name
Wing bolt
Hex. bolt
Wing nut
Spring washer
Flush mount metal
1. Prepare a cutout in the mounting location whose dimensions are 242 (W) X 152
(H) mm.
2. Insert the unit to the cutout.
3. Attach two flush mount metals to the unit with two hex bolts (M6×12) and two
spring washers
4. Screw four wing bolts to wing nut.
5. Fasten the unit with wing bolts assembled at step 4, and then tighten nuts.
1-2
Type
Code No
000-162-608-10
M6×12 SUS304
000-162-897-10
M6 SUS304
000-158-855-10
20-035-1061
100-380-480-10
Type
Code No.
M4×30 YBSC2
000-168-243-10
M6×12 SUS304
000-162-897-10
M4 YBCS2
000-168-239-10
M6 SUS304
000-158-855-10
20-035-1062
100-381-290-10
Qty
4
2
2
1
Qty
4
2
4
2
2

Hide quick links: