Fuel Conversion Procedure
1. Turn off gas supply to stove.
2. Remove the stove Top Plate.
3. Disengage the two Glass Frame Latches and lift the
glass panel frame up and out of the stove.
4. If installed, remove the Embers and Log Set using care
not to damage the fragile log parts.
5. Lift out the Burner Skirt. See fig. 25.
6. Reach under the stove and loosen the Air Shutter
wingnut. Pull the shutter stem back to ease burner
removal.See fig. 26
7. Lift out the Burner Plate with removal of two screws
from the firebox floor. See fig. 27.
8. CHANGE THE INTEGRATED DUAL-FUEL PILOT ORIFICE:
a)
Loosen two sheet metal screws to pivot the Pilot
Shield out of the way as shown in fig. 28.
b)
Use the 7/16" wrench to just loosen the pilot head
enough to push in the adjustment slide. See fig. 29.
LP : push tab to left (red LP indicator is exposed).
NG: push tab to right
9. Change the Burner Injector. See fig. 30. Using a 1/2"
open end wrench or deep-well socket remove the
burner orifice from its brass elbow housing and replace
with the appropriate orifice supplied in the kit.
10. Replace the Burner Plate. Engage the burner tube with
the Air Shutter assembly. Be sure the burner is level and
secure it to the four support brackets with the screws
previously removed.
11. Replace the Valve Regulator. Using a Torx T-20
screwdriver, remove the screws from the front of the
regulator. Remove the regulator components and
replace with the one from the conversion kit. See fig. 31.
12. Install the identification labels to the stove so that they
can be seen by any person who may be servicing the
stove.
Label A: apply to back of stove
Label B: apply to the rating plate attached to the back of
the stove.
Small Conversion Label: apply to valve.
13. Reassemble the stove, apply gas to the system and
check for leaks using a soapy water solution or digital
gas detector.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
Pilot Shield
Figure 28. Use a 1/4" socket driver to loosen two screws
and pivot the Pilot Shield out of the way.
Figure 29. Integrated
dual-fuel pilot orifice- LP
position shown.
Valve Body
Diaphragm
Figure 31.
Regulator tower replacement.
139587_05 GF 200 DV IPI October 2015
LP
Figure 30. Replace the
Burner injector.
Regulator Tower