Exhaust Baffle / Air Deflector Use
Air flow throughout the burner and firebox is critical
to efficient combustion as well as promotion of a
vibrant flame picture. The GF 200 IPI is supplied with
a 2-piece baffle assembly and two air deflector plates
that are intended to provide optimal performance with
either natural gas or propane in a variety of venting
configurations. Use the chart below to set up the firebox
appropriately for your particular installation. See also figs.
10-12.
Secondary Baffle Use - Fig. 11
Fuel Termination
Vent
NG
Horizontal
4/6
NG
Vertical
4/6
LP
Horizontal
4/6
LP
Vertical
4/6
NG
Horizontal
5/8
LP
Horizontal
5/8
Skirt Cover Plate Use - Fig. 12
Fuel Termination Vent
NG
Horizontal
5/8
NG
Vertical
4/6
LP
Horizontal
5/8
LP
Vertical
4/6
Sklrt Cover Plate
10
Installed Removed
X
X
X
X
X
X
Remove and
Install Air
Installed
Deflector
X
X
X
X
Air Deflector
Figure 10.
Remove M6 nut from the Primary Baffle support stud.
Primary Baffle
Figure 11.
Remove the Primary Baffle from Secondary Baffle.
Figure 12.
Vertically Terminated 4/6 Vent:
Remove Burner Skirt Cover Plate and install
Burner Skirt
the Air Deflector to the underside of the
Burner Skirt.
Skirt & Deflector
Primary Baffle
Secondary Baffle
Assembly