Masonry or Prefabricated Chimney
Conversion
IMPORTANT NOTICE
IN THE U.S.,THE USE OF AN EXISTING CHIMNEY AS
AN AIR INTAKE IS NOT COVERED UNDER THE ANSI
Z21.88-1999-CSA 2.33-M99 TEST METHODS AND
RESULTING ITS/WHI PRODUCT CERTIFICATION. THE
CODE AUTHORITY HAVING JURISDICTION MUST
BE CONSULTED PRIOR TO PROCEEDING WITH THIS
INSTALLATION METHOD.
THIS INSTALLATION IS NOT APPROVED IN CANADA.
The GF 200 DV IPI is approved for use with components
of Simpson DuraVent Chimney Kit 46DVA-KMC and
46DVA-KCT in a masonry chimney or a Kits 46DVA-KCA,
46DVA-KCB, and 46DVA-KCC for prefabricated solid fuel
listed chimneys.
These installation requirements must be followed:
Vertically terminated vent runs require 4/6 vent pipe.
Use 4/6 Vent Adaptor Kit 157674. See figs. 13-14.
Use the guidelines for vertical termination shown on
page 11.
In masonry chimney, a fireclay liner or listed steel liner,
must be present the entire length of the chimney.
Chimney height should not exceed 20 ft. (6.09 m).
The liner must have an inside dimension of 6" round or
greater.
Prefabricated chimneys must be UL 103 or ULC S-629
listed and have a minimum INSIDE diameter of 6 inch-
es, (150 mm). Prefabricated chimneys must be listed for
the specific Simpson Dura-Vent Chimney Conversion
Kits noted above.
Exhaust
Gas
Cap Adaptor
4" Flex Pipe
not included
in kit
Support/Wall
Thimble Cover
Figure 18. Vent System through a masonry chimney
using the Simpson Dura-Vent Chimney Conversion Kits.
Drawing is for illustrative purposes only - DO NOT VENT
TWO APPLIANCES INTO A SINGLE CHIMNEY.
139587_05 GF 200 DV IPI October 2015
Vertical Termination Cap
Intake Air
Use Standard
Simpson
Dura-Vent
ProSeries Pipe
from stove to
thimble
13