Default State; Shortcuts - Philips Vari-lite VL3500 Wash User Manual

Hide thumbs Also See for Vari-lite VL3500 Wash:
Table of Contents

Advertisement

To enter the menu system, first press [Menu]. The functions displayed will be 1st level functions.
Scroll through the 1st level functions by pressing [Up] / [Down] arrows. Once the desired function
appears in the display, press [Enter]. You are now at the 2nd level. Once again, press the [Up] /
[Down] arrows to scroll through 2nd level functions. Press [Enter] to access 3rd level functions and so
forth. When the highest level for the function is reached, [Up] / [Down] arrows can be pressed to enter
a value or select a toggle activation such as On/Off. Press [Enter] to store the value or select an action.
For example:

Default State

The menu display's default state during normal operation is to display the DMX address. After 10
seconds of inactivity at the display, it will change to the default state.
After longer periods of inactivity, the menu display will switch to its off state. The default state for this
feature is 5 minutes, however, different time lengths can also be programmed.
To program a different time length for menu off feature:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until
Step 3. Press [Up] / [Down] arrows to access
Step 4. Press [Up] / [Down] arrows to select either
Min

Shortcuts

WARNING: Light Beam Projects Intense Heat
Do not illuminate objects within 3.5 m (11.5 feet) of the VL3500™ Wash Luminaire. Objects within
this range can scorch, melt, or ignite from the heat projected by the light beam.
A few button combinations are provided as shortcuts for frequently used menu functions. These
shortcuts are as follows:
Pressing [Enter] and [Up] at the same time = Lamp On
Pressing [Enter] and [Down] at the same time = Lamp Off
Pressing [Up] and [Down] at the same time inverts or reverts the menu display (only if not set to
Auto)
Pressing [Menu] and [Up] at the same time = Recalibrate
Pressing [Menu] at Power up interrupts calibration. See
Calibrating Luminaire" on page 20
02.96 86.000 1 B
1st Level
Test
(10 minutes), or
(on indefinitely). Press [Enter] to set.
ON
01 J un e 20 09
M
S
ENU
2nd Level
All Seq
Config
(Configuration) appears. Press [Enter].
. Press [Enter].
Display
(30 seconds),
30 Sec
"Program Starting Address Without
for more information.
: M
O
YSTEM
ENU
PERATION
3rd Level
RUN TEST
(5 minutes),
5 Min
4
10
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vari lite vl3500 wash fx luminaires

Table of Contents