Power and Data Cabling Requirements

Power

The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. 10 amps is
required.
Depending on the application, the luminaire's AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code:
WARNING: DO NOT connect to three-phase Delta service in countries with 240 volt power.
Note: The lamp will not strike below 180 volts RMS. The following socket configurations are typical;
other countries can use different socket configurations.
For single-phase power at 200-240 volts RMS:
For three-phase power at 208 volts RMS:
10
L
U
'
ASH
UMINAIRE
SER
Wire *
Green/Yellow
Blue
Brown
Connection
AC Neutral
AC Line
Ground (Earth)
Connection
Phase 1
Phase 2
Ground (Earth)
01 J un e 20 09
M
S
ANUAL
Connection
AC Ground
AC Neutral
AC Line
* International (Harmonized) Standard
Pin
X
X
Y
G
Pin
X
X
Y
G
G
Y
G
Y
02 .9 686 .00 01 B