D-Link Xstack DGS-3600 Series User Manual page 240

Gigabit ethernet managed switch
Hide thumbs Also See for Xstack DGS-3600 Series:
Table of Contents

Advertisement

Replace Dscp
Select this option to instruct the Switch to replace the DSCP value (in a packet that meets the
(0-63)
selected criteria) with the value entered in the adjacent field.
Source IP
Source IP Address - Enter an IP Address mask for the source IP address.
Destination IP
Destination IP Address- Enter an IP Address mask for the destination IP address.
Dscp (0-63)
This field allows the user to enter a DSCP value in the space provided, which will instruct the
Switch to examine the DiffServ Code part of each packet header and use this as the, or part of the
criterion for forwarding. The user may choose a value between 0 and 63.
Protocol
This field allows the user to modify the protocol used to configure the Access Rule Table;
depending on which protocol the user has chosen in the Access Profile Table.
Port
The Access Rule may be configured on a per-port basis by entering the port number of the switch
in the switch stack into this field. When a range of ports is to be configured, the Auto Assign check
box MUST be clicked in the Access ID field of this window. If not, the user will be presented with an
error message and the access rule will not be configured. The beginning and end of the port list
range are separated by a dash. For example, 3 specifies port 3. 2 - 4 specifies the range of ports
from 2 to 4.
Rx rate
Use this to limit Rx bandwidth for the profile being configured. This rate is implemented using the
following equation: 1 value = 64kbit/sec. (ex. If the user selects an Rx rate of 10 then the ingress
rate is 640kbit/sec.) The user many select a value between 1 and 156249 or No Limit. The default
setting is No Limit.
Time Range
Click the check box and enter the name of the Time Range settings that has been previously
configured in the Time Range window. This will set specific times when this access rule will be
implemented on the Switch.
Counter
Click the check box and use the pull-down menu to employ the Counter that will count the packets
identified with this rule. Users must note that if the Counter is employed in the ACL Flow Meter
function, the Counter will automatically be disabled here, regardless of this setting.
To view the settings of a previously correctly configured rule, click
The window shown below will appear.
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
Figure 10- 13. Access Rule Table window
in the Access Rule Table.
223

Advertisement

Table of Contents
loading

Table of Contents