Vent System Identification - Empire Comfort Systems DVX36DP31N-2 Installation Instructions And Owner's Manual

Table of Contents

Advertisement

Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson
Duravent part numbers and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers.
DVVK-4VP
Direct-Vent Fireplace Vent Kit - Vertical, Includes
(DVVK-4V)
46DVA-VCH, 46DVA-SC and 46DVA-F6
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-
DVVK-4TP
the-wall, 8 to 11 inch wall thickness, Includes
(DVVK-4T)
46DVA-08A, 46DVA-09, 46DVA-HC, 46DVA-E90
and 46DVA-WT
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-
DVVK-4TSP
the-wall, 5 to 7 inch wall thickness, Includes
(DVVK-4TS)
46DVA-06, 46DVA-HCC, 46DVA-E90 and
46DVA-WT
DVVK-4FV
Direct-Vent Fireplace Vertical Flex Vent Kit
Direct-Vent Fireplace Vent Kit, Thru-the-wall, 5
DVVK-4RE
to 13 3/4 inch wall thickness
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRESTOP
WALL STRAP
PIPE LENGTH
28653-2-0811

VENT SYSTEM IDENTIFICATION

Figure 51
Available from Empire Comfort Systems, Inc. dealers.
Direct-Vent Fireplace Vent Kit for Rear Vent, 6
DVVK-5RP
to 12 inch wall thickness, Includes 58DVA-06,
(DVVK-5R)
58DVA-WT, and 58DVAHC
Direct-Vent Fireplace Vent Kit for Top Vent,
DVVK-5TP
Thru-the-wall, 4 to 6 inch wall thickness,
(DVVK-5T)
Includes 58DVA-E90, 58DVA-HC, 58DVA-06,
and 58DVA-WT
Direct Vent Fireplace Vent Kit - Vertical,
DVVK-5VP
I n c l u d e s 5 8 D VA - V C H , 5 8 D VA - S C , a n d
(DVVK-5V)
58DVA-F6
Top Vent Kit (Horizontal) - 4½" to 6" wall thickness
DVVK-5TS
(114.3 mm to 152 mm)
DVVK-5F
Horizontal Flex Vent Kit (4' Flex) (1.22m)
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
TWO 90° ELBOWS)
Installing Vent Components (Figure 51)
Begin the vent system installation by installing the first Simpson Duravent
component, 90° elbow to the starting collars or straight pipe on the top
of the appliance, then the straight pipe length and then horizontal or
vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by sliding
the concentric pipe section with four (4) equally spaced interior beads
onto the appliance collar or previously installed component end with
four (4) equally spaced indented sections. When the internal beads
of each starting outer pipe line up, rotate pipe section clockwise 90°
(approximately 3 inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component is securely
fitted and locked into the preceding component in the vent system.
Special DV Vent Kits
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90° ELBOWS)
STORM COLLAR
ROOF FLASHING
Page 33

Advertisement

Table of Contents
loading