Clearance to Combustibles
Back
Side
Floor
Top Stand-off
Top Framing Edge
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
FIRST 6" (SEE
MAGNIFIED VIEW)
TOP FRAMING
LEDGE
GLASS FRONT
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
FRONT FACE (SIDE)
Page 8

CLEARANCES

0" (0 mm)
0" (0 mm)
0" (0 mm)
0" (0 mm)
6" (152 mm)
2" x 4" HEADER
STAND OFF
6" (152mm) HEIGHT
ABOVE TOP OF
FIREPLACE
6"
NAILING
FLANGES
Figure 2
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
FIREPLACE
(TOP VIEW)
3
MAX.
45°
6
PERPENDICULAR
SIDE WALL
Figure 3
Mantel Chart (Figure 4)
12" (305mm)
10" (254mm)
MANTEL
19"
18 3/4"
17"
16"
15"
14"
13"
TOP EDGE OF FIREPLACE
Clearances (Figure 5)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
COMBUSTIBLE TRIM AND
8"
MANTELS ALLOWED IN
SHADED AREA
6"
4 1/2"
3 3/4"
3"
2 1/4"
1 1/2"
3/4"
12"
11"
10"
Figure 4
36"
(914mm)
Figure 5
28653-2-0811