Attention: Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform
to applicable insulation codes.
Vent Runs (Figures 17, 18, and 19)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring.
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL TERMINATION
DVX36,42
50 1/2" (1283mm)
TO BOTTOM
OF UNIT
3" (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
Figure 17