E. Hearth Extension
WARNING! Risk of Fire! Hearth extension required to
protect combustible fl oors in front of appliance.
• An 8 inch minimum hearth extension must be construct-
ed of non-combustible material.
NAILING TABS
(BOTH SIDES)
A
Cerona-36
Cerona-42
Figure 5.6 Hearth Extension Dimensions
The base of the fi replace may sit on a combustible sur-
face. The area in front of the fi replace must be protected
by a noncombustible hearth extension, unless the fi re-
place is raised a minimum of 6 inches above the combus-
tible fl oor or hearth. See Figures 5.6, 5.7 and 5.8.
B
A
B
in.
41-1/8
8
mm
1045
203
in.
48-1/8
8
mm
1222
203
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. W • 9/15
8 in. min.
(203 mm)
1 in. max.
(25 mm)
MARBLE, GRANITE, TILE OR
COMBUSTIBLE
OTHER NON-COMBUSTIBLE
SURFACE

HEARTH EXTENSION

Figure 5.7 Fireplace sitting on combustible surface.
1 INCH MAX.
TO ALLOW FOR
DOOR CLEARANCE
COMBUSTIBLES
UP TO 1 INCH
THICK ALLOWED
UNDER THE OPENING
Figure 5.8 Fireplace raised a minimum of 6 inches away from
combustible surface.
BOTTOM OF
FIREPLACE
SURFACE MAY BE COMBUSTIBLE
6 INCHES
MINIMUM
BOTTOM OF
FIREPLACE
21