4.2.3.21 Belt motor/ High voltage board/ Cover open switch

(1) Remove the scanner. (See Subsection 4.2.1)
(2) Remove the left side cover. (See Subsection 4.2.3.1)
(3) Detach the connector and claw A to remove the cover open switch
(4) Remove a screw (silver)
the high voltage board
(5) Remove a screw (silver)
Claw A
Claw A
Cover opening switch cable route chart
88
and a screw (black)
.
to remove belt motor
Claws A
TR-C
Service Manual
.
, and then detach seven claws B to remove
.
Claws B
High-voltage power supply
TR-M
TR-Y
TR-K
Cover-open switch
Y108500-4