Fax Maintenance
Off-Hook Level
Redial Interval
TX Settings
Redialings
Overseas Comm
Mode
Overseas Comm
Mode Settings
Minimum Time
Length
Dial Pulse Setting
Dial Pulse Type
SM
Sets the off-hook detection threshold.
[10V (Default)/ 15V/ 20V/ 25V 35V]
"Telephone" was indicated by malfunction when
receiving the fax message with some PABX.
Some PABX may output more than 25V to the
FAX input line. Selecting [35V] for [Off-hook
level] by the fax maintenance mode.
Sets the redial interval when Tx fails.
[5 Min/ 6 Min]
Sets the number of redials when Tx fails.
[2 times/ 3 Times/ 4 Times/ 5 Times]
This sets the machine to ignore a DIS signal
sent from the called station once in a sending
operation.
[Off (Default)/ Ignore DIS Once]
If this setting is set to "On", the machine detects
the CNG signal after the line is connected. If it is
set to "Off", the machine detects the CNG signal
as long as the line is connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]
This sets the number of pulses that are
generated during dialing.
N: Dialing '0' generates 10 pulses ---
Dialing '9' generates 9 pulses.
N+1: Dialing '0' generates 1 pulses ---
Dialing '9' generates 10 pulses.
10-N: Dialing '0' generates 10 pulses ---
Dialing '9' generates 1 pulse.
5-15