Section 3. Interface Specifications
NOTE: The signals on pins 1, 3, 4, 6, 9 and 10 each have an open collector output. These pins normally
measure +.07V maximum when a true condition exists. If a false condition occurs, the voltage will drop to
0V. To achieve a signal level of +5V, you must add a 330 ohm, ¼ W pull-up resistor between the open
collector output pin and Vcc (pin 13) as illustrated. This will provide a signal level of +5V for a true
condition and 0V when a false condition exists. The maximum voltage that can be applied to these pins is
+50V and the maximum current they can sink is 500 milliamps.
Vcc= +5V

Standard Operation

Page 3-12
Pin 13
Pin 1, 3, 4, 6, 9 or 10
+5V
Print Start
Input
0V
+5V
Print Repeat
Input
0V
+5V
Print End
Type 1
0V
+5V
Print End
Type 2
0V
+5V
Print End
Type 3
0V
+5V
Print End
Type 4
0V
SATO CL608e/CL612e Service Manual
330 ohm, 1/4W
Start of Print Cycle
20 Milliseconds
Signal Out
End of Print Cycle
PN 9001079