7.3 Clear Head Counters

To reset the printer to the factory settings, perform the following steps.
Caution: Resetting the printer will clear all registers.
STEP
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PN 9001079
Rev.B
PROCEDURE
Record all current dip switch positions, then place all switches in the O..
position.
Place the DSW2-4 in the ON or up postion.
Press the LINE and .EED key while simultaneously turning ON the power
switch. When the printer beeps, release the keys. The following screens will
appear.
initializing
rom v00.00.00.00
Place the DSW-4 in the O.. postion and the following screen will appear.
factory mode
Press the .EED key to display the next screen.
Press the LINE key twice to change the message from NONE to HEAD.
Press the .EED key to clear the Head Counter. After a pause, the next screen
will appear.
Select the print label size by pressing the LINE key. The default is LARGE.
Press the .EED key for a test print. Press the .EED key again to stop printing.
test print
press feed key
Verify that the counters on the test print have reset to 0.0 km.
Power O.. the printer and confirm that all switches are in the O.. or down
position.
SATO CL608e/CL612e Service Manual
maintenance mode
dipsww2-4 on->off
The Head Counter will be
cleared by the following
steps:
counter clear
none
counter clear
head
print size
small large
Warning: This test activates all the heating
elements on the print head and therefore
should be used for testing purposes only with
full width labels to avoid damaging the print
head.