Interlogix Alliance system User Manual page 74

Table of Contents

Advertisement

68
Alliance system
User Manual
Term
DGP
Dialer
Disarmed
Door contact
Door control
Door group
Dual detector
Duress
Engineer
Event flags
History
Hold-up
Installer
Keypad
Keyswitch
LCD
LED
Local alarm
Logic equation
Macro input
Macro logic program
Macro output
Definition
(Data Gathering Panel) A device that collects data from other security devices within an area, and
transfers it to the main control panel or 4-door DGP.
An electronic device that allows the system to transmit alarms and other events to a central
station. It can also be used to perform up/download.
The condition of an occupied area when the security system has been set so that normal activity
does not set off an alarm.
A magnetic contact used to detect if a door or window is opened.
The control over door functions.
A feature that assigns a group of doors to a user, in order to allow the user access to those doors.
Access to each door in a group can be restricted via a time zone.
A security device based on two techniques, such as PIR and RADAR or PIR and Ultrasonic, used
to detect intruders in an area or premise.
When a user is being forced to breach the system security (e.g. forced at gunpoint to open the
door), the duress feature allows the user to signal a central station by entering a duress digit in
conjunction with a PIN code.
Installer employee qualified to install and service the control panel.
A signal activated by a zone input condition, area condition, system status or fault condition, door
command (on doors 1 to 16), or shunt condition. The main purpose of an event flag is to activate
an output.
A list of past alarm and access control events stored in memory that can be viewed on an LCD
arming station or sent to a printer.
An alarm (silent) triggered by a hold-up button only sends a message to a central station.
A company that installs and services security equipment.
A remote arming station (RAS) with keys to input data used to program the control panel, perform
user functions, view alarms, etc.
A device using a switch with a key to arm or disarm areas.
(Liquid Crystal Display) The part of a remote arming station (RAS) where messages are displayed.
(Light Emitting Diode) A light indicator on an arming station, which conveys a condition (e.g. area
in alarm, communication fault, etc).
An alarm that occurs in an occupied area and is signaled within a premise and not reported to a
central station.
A logic expression that combines macro inputs in a specific manner. The result of a logic equation
is called a macro output.
An event flag or an output that is used in a logic equation. Each macro input is an event flag or output.
A set of rules that is created by macro inputs, logic equations and macro outputs that is used to
trigger event flags or zone inputs.
A macro output holds the result of a logic equation. The macro output can have a timing element.
Macro outputs trigger event flags or zone inputs.

Advertisement

Table of Contents
loading

Table of Contents