LE 05 Command Center
LE 05 Command Center
LE 05 Command Center
LE 05 Command Center
Safety Concept
Safety Concept
Requirements
The device's system settings
have to be protected.
In addition to system settings,
any unauthorized device
configuration
should generally be
prevented.
prevented
System settings must be
protected from access via the
Command Center.
Only selected communication
protocols must be used.
Only certain interfaces must
be used.
Only certain PCs must be allowed
to access the device.
Access to the device / Command
Center must only be
granted to certain persons.
Specific use of the device is
granted to certain persons.
Measure
The system settings are protected by a standard account (DeviceAdmin)
(FS-6025: 2500 / 2500 and FS-6030: 3000 / 3000
This standard account should be changed as required to ensure long-term
security.
security.
It is also practical to set up an additional account to ensure access if the
"official" password is lost or unknown (should be arranged with the
customer).
See page Authentication
Access to the Command Center is protected by a standard password
(admin00). This standard password should be changed as required to
ensure long-term security.
It is also practical to set up an additional account (see User Login) to
ensure access if the "official" password is lost or unknown.
See page Network safety
See page Blocking the Interfaces
See page IP-Filter
Local Authentication
Local authentication linked to a cost center.