Changing Max. / Min Values In Run Mode - Panasonic MICRO-IMAGECHECKER AX40 User Manual

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

7.5.6 Changing Max. / Min Values in RUN Mode

You can change Max./ Min. values of the numeric calculations that are quoted to the data monitor.
Setting Procedure
When data monitor is displayed in RUN mode, follow the steps below.
1.
Highlight the Max. /Min. values of the
desired items in the Data Monitor table.
READY signal is turned off and the subwindow is
displayed.
2.
Highlight the Max. /Min. cell.
The cursor moves to a cell in which a value is.
3.
Change the value and press the ENTER key.
4.
Press the C key.
After the subwindow disappears, READY signal is turned on.
The device does not accept any signal including START signal (not including key emulation
command) from the external device while READY signal is off. Therefore, START signal input
from the external equipment does not trigger inspection.