6.15.2 Registering a Base Position
The current object position can be registered as a base position in the following way. Before registering
the base position, check to make sure that the edges were detected by setting the horizontal/vertical
areas and performing a testing. When a live image is displayed, perform a test after importing a new
image. When a memory image is displayed, perform a test using the memory image currently displayed
without importing any images.
Registration Procedure
1.
Select the "Base Position" tab.
The cursor moves to "Base Setting".
2.
Press the ENTER key.
When the dialog message appears, choose "YES" to continue.
If the edges were correctly detected and the base position was registered, the following data appears.
In the Base Position tab
Corr.: Correspondence value of the highest correlation value
Adj. X: 0.0
Adj. Y: 0.0
Base Pos. X: Coordinate X of the highest correlation value
Base Pos. Y: Coordinate Y of the highest correlation value
In the Message Area tab
Judgement: OK
Corr.: Correspondence value of the highest correlation value
Adj. X: 0.0
Adj. Y: 0.0
If the following message appears, it means horizontal and vertical edges are not detected. Check the
setting values of areas (positions of start and end points) or the inspection objects.
E0042 Base position cannot be detected.