Summary of Contents for Vega VEGAPULS 66

  • Page 1 Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 66 Profibus PA Standpipe version Document ID: 47150...
  • Page 2: Table Of Contents

    Operating Instructions Manual as well as the Safety Manual that comes with instruments with SIL qualification. These manuals are available on our homepage. Operating instructions VEGAPULS 66 - Profibus PA - Standpipe version: Document-ID 36525 Editing status of the quick setup guide: 2021-06-10...
  • Page 3: For Your Safety

    During work on and with the device, the required personal protective equipment must always be worn. Appropriate use VEGAPULS 66 is a sensor for continuous level measurement. You can find detailed information about the area of application in chapter " Product description".
  • Page 4: Eu Conformity

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause interference, and • This device must accept any interference, including interference that may cause undesired operation of the device VEGAPULS 66 • Profibus PA...
  • Page 5: Environmental Instructions

    The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: • Chapter " Packaging, transport and storage" • Chapter " Disposal" VEGAPULS 66 • Profibus PA...
  • Page 6: Product Description

    Alternatively, you can access the data via your smartphone: • Download the VEGA Tools app from the " Apple App Store" or the " Google Play Store" • Scan the DataMatrix code on the type label of the instrument or •...
  • Page 7: Mounting

    2. The measurement is only possible inside the tube, the standpipe antenna must hence reach up to the requested min. level For further information see chapter " Mounting". VEGAPULS 66 • Profibus PA...
  • Page 8: Connecting To The Bus System

    7. Check the hold of the wires in the terminals by lightly pulling on them 8. Connect the shielding to the internal ground terminal, connect the external ground terminal to potential equalisation VEGAPULS 66 • Profibus PA...
  • Page 9: Wiring Plan, Single Chamber Housing

    6 7 8 Fig. 4: Connection compartment - double chamber housing Voltage supply, signal output For display and adjustment module or interface adapter For external display and adjustment unit Ground terminal for connection of the cable screening VEGAPULS 66 • Profibus PA...
  • Page 10 4 Connecting to the bus system Information: Parallel use of an external display and adjustment unit and a display and adjustment module in the connection compartment is not sup- ported. VEGAPULS 66 • Profibus PA...
  • Page 11: Set Up With The Display And Adjustment Module

    The display and adjustment module is powered by the sensor, an ad- ditional connection is not necessary. Fig. 5: Installing the display and adjustment module in the electronics compart- ment of the single chamber housing VEGAPULS 66 • Profibus PA...
  • Page 12: Parameter Adjustment

    The radar sensor measures the distance from the sensor to the Parameterization example medium surface. For indication of the real level, an allocation of the measured distance to the percentage height must be carried out. VEGAPULS 66 • Profibus PA...
  • Page 13 Additional settings - False The following circumstances cause interfering reflections and can signal suppression influence the measurement: • High mounting nozzles • Vessel internals such as struts • Agitators • Buildup or welded joints on vessel walls VEGAPULS 66 • Profibus PA...
  • Page 14 When selecting " Extend", the distance to the medium surface of the created false signal suppression is displayed. This value can now be changed and the false signal suppression can be extended to this range. VEGAPULS 66 • Profibus PA...
  • Page 15: Menu Overview

    Filling height in % Backlight Switched on Diagnostics Menu item Parameter Default setting Device status Peak value indi- Distance cator Electronics tem- Temperature perature, further Measurement re- liability Simulation Percent Curve display Echo curve False signal sup- pression VEGAPULS 66 • Profibus PA...
  • Page 16 Actual date/Actual time Reset Copy instrument settings - Info Menu item Parameter Device name VEGAPULS 6. Instrument version Hardware and software version Date of manufacture Date Profibus ident number 4-digit, hexadecimal Instrument features Order-specific characteristics VEGAPULS 66 • Profibus PA...
  • Page 17: Set Up With Smartphone/Tablet, Pc/Notebook Via Bluetooth

    1. In the adjustment menu, go to " Additional adjustments", " PIN" Note: The menu item " PIN" is only displayed if in the menu " Setup", " Lock/ Unlock adjustment" the adjustment is released. 2. Change sensor PIN VEGAPULS 66 • Profibus PA...
  • Page 18: Connecting

    Bluetooth-capable instru- ments in the area. PC/Notebook Start PACTware and the VEGA project assistant. Select the device search via Bluetooth and start the search function. The device auto- matically searches for Bluetooth-capable devices in the vicinity.
  • Page 19 6 Set up with smartphone/tablet, PC/notebook via Bluetooth App view Fig. 9: Example of an app view - Setup sensor adjustment VEGAPULS 66 • Profibus PA...
  • Page 20: Supplement

    9 … 32 V DC Operating voltage - with Bluetooth 11.6 … 32 V DC switched on Operating voltage U with lighting 13.5 … 32 V DC switched on Number of sensors per DP/PA segment coupler, max. VEGAPULS 66 • Profibus PA...
  • Page 21 Notes VEGAPULS 66 • Profibus PA...
  • Page 22 Notes VEGAPULS 66 • Profibus PA...