Sign In
Upload
Manuals
Brands
In-situ Manuals
Measuring Instruments
Aqua TROLL 600
In-situ Aqua TROLL 600 Manuals
Manuals and User Guides for In-situ Aqua TROLL 600. We have
11
In-situ Aqua TROLL 600 manuals available for free PDF download: Operator's Manual, Quick Start Manual, Instruction Sheet, Overview, Instruction Manual
In-situ Aqua TROLL 600 Operator's Manual (138 pages)
Brand:
In-situ
| Category:
Data Loggers
| Size: 4.7 MB
Table of Contents
Table of Contents
2
Introduction
9
Serial Number Location
9
Instrument Description
9
Document Conventions
9
Unpacking and Inspection
9
Obtaining Repair Service
9
Outside the U
10
Guidelines for Cleaning Returned Equipment
10
Decontamination and Cleaning Form
11
Safety
11
General Specifications
12
Instrument Dimensions with Restrictor
14
Instrument Dimensions with Restrictor off
14
Sensor Specifications
15
Sensor Summary
15
Potential Interferents
16
RDO Cap Chemical Incompatibility
16
Conductivity/Temperature Sensor
16
Instrument Overview
25
Synopsis
25
System Components
26
Base Unit Components
26
Ruggedcable System
27
Vented or Non-Vented Cable
28
Jacket Options
28
Customizable Cable Lengths
28
Cable Termination
28
Instrument Setup
29
Box Contents
29
Install the Batteries
30
Desiccant
30
Replace the Desiccant
31
Install the Wiper Motor and Sensors
31
Handling Ph and Ion-Selective Electrode Sensors (Ises)
34
Using the RDO Sensor and RDO Fast Cap
34
Ion-Selective Electrode Sensor (ISE) Requirements
35
Ammonium Sensor Requirements
35
Chloride, Nitrate, and Ph/Orp Sensor Requirements
35
Removing Sensors
36
Connecting to the Sonde
36
Connect the Instrument to the Ruggedcable
36
Connect TROLL Com Communication Device to the Ruggedcable System
36
Connecting with Bluetooth
36
Connecting to Vusitu
37
Connecting to a Wireless TROLL Com
37
Connecting to Win-Situ 5
37
SDI-12 3-Wire
38
Modbus Master
39
Modbus Master with RS232 (Converter Required)
40
Modbus PLC Interface
41
LCD Screen
44
Accessing the LCD Menu
44
Possible Port Statuses
44
Possible Power Statuses
44
Possible Connected Statuses
44
Error Messages
44
Micro SD Card
47
Desiccant
49
Replace the Desiccant
49
Sensor Calibration
49
Recommended Calibration Equipment, Accessories and Solutions
49
Laboratory/Office Calibration
49
Field Calibration
49
Solution Based Calibration Preparation, Procedure and Rinsing
50
RDO 100% Saturation Calibration
51
Option 1 - Water Saturated Air
51
Option 2 - Saturation Bubbler
52
Verification of Calibration Accuracy
52
Calibration Frequency Recommendations
53
Factory Calibration
54
Zeroing the Depth Sensor
55
Software
57
Vusitu Mobile App
57
Verify the Vusitu Mobile App Version
57
Connecting with Bluetooth
57
Connecting to Vusitu
57
Vusitu Overview
57
About Vusitu
57
Vusitu Menu Options
58
Menu Options When Connected to Instrument
58
Selecting with Long-Press and Swipe
58
Long Press
58
Swipe Left
58
Swipe Right
58
Live Readings in Vusitu
59
Snapshot Mode
59
Live Readings Mode
59
Exporting Data Files
60
Viewing Data Files
60
Vusitu Locations
61
About Vusitu Locations
61
Create a New Location
61
Select a Location
62
Edit or Delete a Location
63
Vusitu Data
64
Downloading and Sharing Your Data
64
Vusitu Calibration and Settings
65
About Calibration and Settings
65
Quick-Cal Multiple Sensor Calibration
65
Calibrate the Rugged Dissolved Oxygen Sensor (1-Point)
67
100% Water-Saturated Air Calibration
68
Option 1 - Water Saturated Air
68
Option 2 - Bubbler
68
0-Point Calibration
69
Calibrating Using Concentration
70
Calibrate the Rugged Dissolved Oxygen Sensor (2-Point)
70
100% Water-Saturated Air Calibration
70
Option 1 - Water Saturated Air
70
Option 2 - Bubbler
71
0-Point Calibration
71
Calibrating the Rugged Dissolved Oxygen Sensor Using Concentration
72
RDO Salinity Setting
72
Calibrate the Conductivity Sensor
73
Calibrate the Level Sensor
76
Calibrate the Ph Sensor
76
Calibrate the ORP Sensor
78
Calibrate the Turbidity Sensor
80
Calibrate the Ammonium Sensor
83
Calibrate the Chloride Sensor
85
Calibrate the Nitrate Sensor
86
Win-Situ 5
88
Data Tab
88
Home Tab
90
Logging Tab
92
Log Information
92
Log Status
93
Log Control Buttons
93
Log Operations
93
Sensors Tab
94
Calibrate
94
Device Setup Tab
95
Device Information
95
Manual Time Set
95
Device Firmware Update
95
Device Status
95
Factory Reset
96
Analog Setup
96
SDI-12 Setup
96
Alarm Setup
96
Modbus Setup
96
Win-Situ 5 Logging and Viewing Data
96
About Sites
96
Logging Data-Overview
97
Logging Method Descriptions
97
Logging Methods for Long-Term Monitoring
97
Linear
97
Linear Average
97
Event
98
Log Setup
98
Starting a Log
98
Starting a Pending Log
98
Starting a Manual Log
99
Suspending (Pausing) a Log
99
Resuming a Suspended Log
99
Stopping a Log
99
Restarting a Log
99
Downloading Data to a
100
Viewing Logged Data
100
Exporting Data
100
Exporting Data to Spreadsheet Format
100
Exporting to Text
101
Graphing Data
101
View a Graph of a Downloaded File
101
View a Graph of Real-Time Data
101
Graph Settings
101
Graph Templates
101
Graph Tools
101
Calibration
103
Calibrate Sensors
103
Calibrating the Conductivity Sensor
103
Nominal Stability Vs� Full Stability
105
Calibrating the Pressure Sensor
105
Calibrating the RDO Sensor
106
Calibrate 100% Oxygen Saturation
107
Nominal Stability Vs� Full Stability
107
Calibrate 0% Oxygen Saturation
108
Calibrating the Ph/Orp Sensor
108
Nominal Stability Vs� Full Stability
109
Calibrating the Turbidity Sensor
109
Calibrating the Ammonium Sensor
111
Calibrating the Chloride Sensor
112
Calibrating the Nitrate Sensor
112
Calibration Reports
113
Baromerge
114
Using Baromerge Software
114
Baro Merge Input-Manual Entry
114
Baro Merge Input-Fixed Correction
115
Baromerge Input-Barotroll File
116
Baromerge Output
117
Post Level Correction Within Baro Merge
117
Managing Data from Multiple Sites
118
Adding a Site
118
Editing a Site
118
Deleting a Site
118
Using Site Groups
118
Creating a Site Group
118
Site-Based Connections
119
Creating a Custom Connection
119
Using a Custom Connection
119
Storing Custom Connection for a Site
119
Correcting a Level Reference in Data Files
119
About Post Correcting Level Data
119
Open Post Level Correction
120
Select Level Reference Type
120
Set the Level Correction
121
View Post Level Corrected Data
122
Importing Vusitu Data to Win-Situ
122
Win-Situ 5 Troubleshooting
123
Selecting the Correct COM Port
123
Steps for Windows 8�1 and Windows 10 Systems
123
Steps for Windows 8 Systems
123
Steps for Windows 7 Systems
123
Steps for Windows XP Systems
124
Bluetooth Connection
124
Care and Maintenance
125
Maintenance Schedule
125
User-Serviceable Parts
125
O-Rings
125
Ph/Orp Sensor Replacement
125
RDO Sensor Cap Replacement
125
Instrument Storage
125
Short-Term Storage (Less than 1 Week)
125
Long-Term Storage (more than 1 Week)
125
Cleaning the Sonde
126
Cleaning and Storing the Ph/Orp Sensor
126
Routine Maintenance
126
Replacing the Filling Solution
126
Replacing the Junction
127
Cleaning
127
Short-Term Storage
127
Long-Term Storage
128
Storage Recommendations
128
Cleaning and Storing the RDO Sensor
128
Routine Maintenance
128
Cleaning the Optical Window
128
Storage
128
Cleaning and Storing the Conductivity Sensor
129
Cleaning
129
Storage
129
Cleaning and Storing the Turbidity Sensor
129
Routine Maintenance
129
Storage
130
Replacing Wiper Bristles
130
Replacing Just the Bristles
130
Replacing the Entire Brush
130
Cleaning the Copper Antifouling Restrictor
130
Declaration of Conformity
131
Appendix
132
Appendix A: Parameter Discovery
132
Appendix B: Parameter Numbers and Locations
133
Appendix C: Unit Ids
135
Appendix D: Register Data Formats
138
Advertisement
In-situ Aqua TROLL 600 Operator's Manual (125 pages)
Multiparameter Sonde
Brand:
In-situ
| Category:
Measuring Instruments
| Size: 2.47 MB
Table of Contents
Table of Contents
3
1 Introduction
10
Serial Number Location
10
Instrument Description
10
Document Conventions
10
Unpacking and Inspection
10
Obtaining Repair Service
11
Guidelines for Cleaning Returned Equipment
11
Decontamination and Cleaning Form
13
Safety
13
2 General Specifications
14
Instrument Dimensions with Restrictor on
16
Instrument Dimensions with Restrictor off
16
3 Sensor Specifications
16
Sensor Summary
16
Barometric Pressure Sensor Specifications
17
Conductivity Sensor Specifications
17
Total Dissolved Solids
18
Salinity
18
Dissolved Oxygen RDO Sensor Specifications
18
Level, Depth, Pressure Sensor Specifications
19
ORP Sensor Specifications
20
Ph Sensor Specifications
20
Temperature Sensor Specifications
20
Turbidity Sensor Specifications
21
Total Suspended Solids
21
4 Instrument Overview
22
Synopsis
22
System Components
23
Base Unit Components
23
Accessories Purchased Separately
23
Ruggedcable System
25
Vented or Non-Vented Cable
25
Jacket Options
25
Customizable Cable Lengths
25
Cable Termination
25
5 Instrument Setup
27
Box Contents
27
Install the Batteries
28
Desiccant
29
Replace the Desiccant
29
Install the Wiper Motor and Sensors
29
Removing Sensors
31
6 Connecting to the Sonde
32
Connecting Ruggedcable
32
Connect the Instrument to the Ruggedcable
32
Connect TROLL Com Communication Device to the Ruggedcable System
32
Connecting with Bluetooth
33
Connecting to a Wireless TROLL Com
33
SDI-12 3 Wire
34
Modbus Master
36
Modbus Master with RS232 (Converter Required)
37
7 LCD Screen
37
Turn on the LCD Screen
38
Status Icons
38
Additional LCD Icons
39
Full-Text Messages
39
Sonde Menus
40
Accessing the Sonde Menus
40
Data Log Menu
40
Start a Log
40
Stop a Log
41
Contrast Menu
41
Language Menu
41
Updates Menu
41
8 Batteries
41
Battery Replacement
42
9 Micro SD Card
42
Removing the Micro SD Card
42
Downloading and Deleting Data from the Micro SD Card
42
Updating Firmware
43
10 Desiccant
43
Replace the Desiccant
43
11 Sensor Calibration
44
Preparing the Aqua TROLL 600 for Calibration
44
Calibration Recommendations
44
Factory Calibration
45
12 Software
46
13 Vusitu Mobile App
46
Verify the Vusitu Mobile App Version
46
Connecting with Bluetooth
46
Vusitu Overview
48
About Vusitu
48
Vusitu Menu Options
48
Menu Options When Connected to Instrument
48
Live Readings Screen
49
Changing Parameters and Units
51
Record Data
51
Vusitu Locations
52
About Vusitu Locations
52
Create a New Location
53
Select a Location
54
Edit or Delete a Location
55
Vusitu Data
56
About Data
56
View, Send, Delete Data
56
Vusitu Calibration & Settings
57
About Calibration and Settings
57
Quick-Cal Multiple Sensor Calibration
57
Calibrate the Rugged Dissolved Oxygen Sensor (1-Point)
59
100% Water-Saturated Air Calibration
59
Calibrate the Rugged Dissolved Oxygen Sensor (2-Point)
60
100% Water-Saturated Air Calibration
60
0-Point Calibration
61
Calibrating the Rugged Dissolved Oxygen Sensor Using Concentration
61
RDO Salinity Setting
62
Calibrate the Conductivity Sensor
64
Calibrate the Level Sensor
66
Calibrate the Ph Sensor
66
Calibrate the ORP Sensor
67
Calibrate the Turbidity Sensor
69
14 Win-Situ 5
70
Verify the Win-Situ Software Version
70
Win-Situ 5 Screens and Buttons
70
Data Tab
70
Home Tab
72
Logging Tab
74
Sensors Tab
76
Device Setup Tab
77
Win-Situ 5 Logging and Viewing Data
79
About Sites
79
Logging Data-Overview
80
Logging Method Descriptions
80
Linear
80
Linear Average
80
Logging Methods for Long-Term Monitoring
80
Event
81
Log Setup
81
Starting a Log
82
Starting a Manual Log
82
Starting a Pending Log
82
Suspending (Pausing) a Log
82
Resuming a Suspended Log
82
Stopping a Log
82
Restarting a Log
83
Downloading Data to a PC
83
Viewing Logged Data
84
Exporting Data
84
Exporting Data to Spreadsheet Format
84
Exporting to Text
85
Graphing Data
85
Graph Settings
85
Graph Templates
85
Graph Tools
85
View a Graph of a Downloaded File
85
View a Graph of Real-Time Data
85
Calibration
87
Calibrate Sensors
87
Calibrating the Conductivity Sensor
87
Calibrating the Pressure Sensor
89
Calibrating the RDO Sensor
90
Calibrate 100% Oxygen Saturation
91
Calibrate 0% Oxygen Saturation
92
Calibrating the Ph/Orp Sensor
92
Calibrating the Turbidity Sensor
94
Calibration Reports
96
Saving Calibration Reports
96
Viewing Calibration Reports
96
Baromerge
96
Using Baromerge Software
96
Baro Merge Input-Manual Entry
97
Baro Merge Input-Fixed Correction
98
Baromerge Input-Barotroll File
99
Baromerge Output
100
Post Level Correction Within Baro Merge
100
Managing Data from Multiple Sites
101
Adding a Site
101
Editing a Site
101
Deleting a Site
101
Using Site Groups
101
Creating a Site Group
102
Site-Based Connections
102
Creating a Custom Connection
102
Using a Custom Connection
102
Storing Custom Connection for a Site
102
Correcting a Level Reference in Data Files
103
About Post Correcting Level Data
103
Open Post Level Correction
103
Select Level Reference Type
104
Set the Level Correction
105
View Post Level Corrected Data
106
Win-Situ 5 Troubleshooting
106
Selecting the Correct COM Port
106
Bluetooth Connection
107
15 Water Quality
108
What Is Ph
108
Why Measure Ph
108
The Ph/Orp Sensor
109
Oxidation-Reduction Potential
110
What Is ORP
110
Why Measure ORP
110
The Ph/Orp Sensor
111
Conductivity
111
What Is Conductivity
111
Why Measure Conductivity
112
How Is Conductivity Measured
112
Dissolved Oxygen
113
What Is Dissolved Oxygen
113
Why Measure DO
113
How Is DO Measured
113
Turbidity
114
What Is Turbidity
114
Why Measure Turbidity
114
How Is Turbidity Measured
115
16 Care and Maintenance
117
Maintenance Schedule
117
User-Serviceable Parts
117
O-Rings
117
Ph/Orp Sensor Replacement
117
RDO Sensor Cap Replacement
117
Instrument Storage
117
Short-Term Storage (<1 Week)
117
Long-Term Storage (>1 Week)
117
Cleaning the Sonde
118
Cleaning and Storing the Ph/Orp Sensor
118
Routine Maintenance
118
Replacing the Filling Solution
119
Replacing the Junction
119
Cleaning
119
Short-Term Storage
120
Long-Term Storage
120
Storage Recommendations
120
Cleaning and Storing the RDO Sensor
121
Routine Maintenance
121
Cleaning the Optical Window
121
Storage
121
Cleaning and Storing the Conductivity Sensor
121
Cleaning
121
Storage
122
Cleaning and Storing the Turbidity Sensor
122
Routine Maintenance
122
Replacing Wiper Bristles
123
Replace the Bristles
123
Replace the Entire Brush
123
Cleaning the Copper Antifouling Restrictor
124
17 Declaration of Conformity
125
In-situ Aqua TROLL 600 Operator's Manual (82 pages)
Brand:
In-situ
| Category:
Engine
| Size: 10.45 MB
Table of Contents
Table of Contents
2
Introduction
6
Serial Number Location
6
Instrument Description
6
Document Conventions
6
Unpacking and Inspecting
6
Obtaining Repair Service
7
Guidelines for Cleaning Returned Equipment
8
Safety
9
Intended Use
9
Instrument Specifications
10
External Power Source Requirements
11
Sensor Specifications
13
Sensor Summary
13
Solutions
14
Potential Interferents
15
RDO Cap Chemical Incompatibility
15
Conductivity/Temperature Sensor
15
Ammonium, Chloride, and Nitrate Interferent Concentrations
16
Required Accessories
18
Communication Device
18
Cable
19
Software
23
Getting Started
24
Handling Ph and Ion-Selective Electrode Sensors (Ises)
27
Ammonium Sensor Requirements
28
Chloride, Nitrate, and Ph/Orp Sensor Requirements
28
LCD Screen
30
Accessing the LCD Menu
30
Possible Power Statuses
30
Possible Connected Statuses
30
Possible Port Statuses
30
Possible Log Statuses
30
Error Messages
31
Starting a Log with the LCD Menu
31
Stopping a Log
31
Adjusting the LCD Menu Contrast
32
Setting or Changing Menu Language
33
Micro SD Card
33
Replacing Desiccant
34
Calibrating Sensors
34
Solution-Based Calibration
34
RDO 100% Saturation Calibration: Water Saturated Air
35
RDO 100% Saturation Calibration: Saturation Bubbler
36
RDO Salinity Setting
36
Zeroing the Depth Sensor
37
Calibration Frequency Recommendations
39
Batch Calibrating Sensors in Vusitu
41
Different Sensor Types (Quick Cal Solution)
41
Multiple Sensors of the same Type
42
Navigating Vusitu
43
Vusitu Mobile App
43
Connected Instrument Screen
43
Vusitu Menu Options
44
Selecting with Long-Press and Swipe
44
Hydrovu
45
Live Readings in Vusitu
46
Snapshot Mode
46
Live Readings Mode
46
Vusitu Data
47
Downloading Your Data
47
Sharing Data
47
Viewing Data on a Mac or PC
47
Vusitu Locations
48
About Vusitu Locations
48
How to Create a Location
48
How to Select a Location
49
How to Edit or Delete a Location
49
Logging
50
How to Create a Log with Vusitu
50
Remote-Monitoring Configuration (Telemetry)
51
Connecting to Win-Situ on a PC
53
Connecting to Win-Situ Via USB
53
Navigating the Win-Situ Interface
54
Home Tab
54
Sensor Tab
54
Device Setup Tab
55
Logging Tab
55
Baromerge
56
Connecting the Aqua TROLL 600 to a PLC or Data Logger
60
Configuring SDI-12 Settings
63
About SDI-12
63
Configure SDI-12 Settings in Vusitu
63
Modbus PLC Interface
63
Overview
63
Setting up Instrument
64
Programming the PLC
64
Reading Parameters
65
Care and Maintenance
66
Maintenance Schedule
66
User-Serviceable Parts
66
Storage
66
Cleaning the Sonde
67
Cleaning and Storing the Ph/Orp Sensor
67
Cleaning and Storing the RDO Sensor
69
Cleaning and Storing the Conductivity Sensor
70
Cleaning and Storing the Turbidity Sensor
71
More Information
72
Declaration of Conformity
73
Appendix
75
Appendix A: Parameter Discovery
75
Advertisement
In-situ Aqua TROLL 600 Operator's Manual (74 pages)
Brand:
In-situ
| Category:
Measuring Instruments
| Size: 4.23 MB
Table of Contents
Table of Contents
2
Introduction
5
Purpose
5
Serial Number Location
5
Instrument Description
5
Document Conventions
5
Unpacking and Inspecting
5
Obtaining Repair Service
6
Guidelines for Cleaning Returned Equipment
7
Safety
8
General Specifications
9
External Power Source Requirements
10
Sensor Specifications
12
Sensor Summary
12
Potential Interferents
13
RDO Cap Chemical Incompatibility
13
Conductivity/Temperature Sensor
13
Instrument Overview
22
System Components
23
Base Unit Components
23
Getting Started
26
Handling Ph and Ion-Selective Electrode Sensors (Ises)
30
Using the RDO Sensor and RDO Fast Cap
30
Ion-Selective Electrode Sensor (ISE) Requirements
31
Ammonium Sensor Requirements
31
Chloride, Nitrate, and Ph/Orp Sensor Requirements
31
SDI-12 3-Wire
32
Modbus Master
33
Modbus Master with RS232 (Converter Required)
34
Modbus PLC Interface
35
LCD Screen
38
Accessing the LCD Menu
38
Possible Port Statuses
38
Possible Power Statuses
38
Possible Connected Statuses
38
Error Messages
38
Starting a Log with the LCD Menu
39
Stopping a Log
39
Stopping a Log
40
Adjusting the LCD Menu Contrast
40
Setting or Changing Menu Language
41
Viewing the Updates Menu
41
Micro SD Card
42
Replacing Desiccant
44
Sensor Calibration
44
Solution-Based Calibration
44
Turbidity Sensor Calibration
45
RDO 100% Saturation Calibration: Water Saturated Air
46
RDO 100% Saturation Calibration: Saturation Bubbler
46
RDO Salinity Setting
47
Zeroing the Depth Sensor
50
Software
52
Vusitu Mobile App
52
Vusitu Overview
52
Vusitu Menu Options
53
Selecting with Long-Press and Swipe
53
Vusitu Data
54
Downloading Your Data
54
Sharing Data
54
Viewing Data on a Mac or PC
54
Live Readings in Vusitu
55
Snapshot Mode
55
Live Readings Mode
55
Exporting Data Files
56
Viewing Data Files
56
Vusitu Locations
57
About Vusitu Locations
57
How to Create a Location
57
Care and Maintenance
60
Maintenance Schedule
60
User-Serviceable Parts
60
Storage
60
Cleaning the Sonde
61
Cleaning and Storing the Ph/Orp Sensor
61
Cleaning and Storing the RDO Sensor
63
Cleaning and Storing the Conductivity Sensor
64
Cleaning and Storing the Turbidity Sensor
65
Declaration of Conformity
67
Appendix
68
Appendix A: Parameter Discovery
68
Appendix B: Parameter Numbers and Locations
69
Appendix C: Unit Ids
71
Appendix D: Register Data Formats
74
In-situ Aqua TROLL 600 Quick Start Manual (4 pages)
Brand:
In-situ
| Category:
Measuring Instruments
| Size: 1.67 MB
In-situ Aqua TROLL 600 Quick Start Manual (4 pages)
Brand:
In-situ
| Category:
Measuring Instruments
| Size: 0.53 MB
In-situ Aqua TROLL 600 Instruction Sheet (3 pages)
pH/ORP Sensor
Brand:
In-situ
| Category:
Accessories
| Size: 0.36 MB
In-situ Aqua TROLL 600 Instruction Sheet (3 pages)
Sensor Overview
Brand:
In-situ
| Category:
Accessories
| Size: 1.01 MB
In-situ Aqua TROLL 600 Overview (3 pages)
pH/ORP Sensor
Brand:
In-situ
| Category:
Accessories
| Size: 0.9 MB
In-situ Aqua TROLL 600 Instruction Manual (3 pages)
pH/ORP Sensor
Brand:
In-situ
| Category:
Test Equipment
| Size: 0.71 MB
In-situ Aqua TROLL 600 Instruction Sheet (2 pages)
BGA-PC Sensor
Brand:
In-situ
| Category:
Accessories
| Size: 0.67 MB
Advertisement
Related Products
In-situ Rugged TROLL 100
In-situ Rugged TROLL 200
In-situ Level TROLL 400
In-situ Level TROLL 500
In-situ Level TROLL 700
In-situ MP TROLL 9500
In-situ Level Troll 300
In-situ TROLL 101
In-situ TROLL 201
In-situ Aqua TROLL 800
In-situ Categories
Measuring Instruments
Data Loggers
Accessories
Test Equipment
Cables and connectors
More In-situ Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL