Sign In
Upload
Manuals
Brands
DEUTSCHMANN AUTOMATION Manuals
Gateway
UNIGATE SC232/485
DEUTSCHMANN AUTOMATION UNIGATE SC232/485 Manuals
Manuals and User Guides for DEUTSCHMANN AUTOMATION UNIGATE SC232/485. We have
3
DEUTSCHMANN AUTOMATION UNIGATE SC232/485 manuals available for free PDF download: Instruction Manual
DEUTSCHMANN AUTOMATION UNIGATE SC232/485 Instruction Manual (67 pages)
Universal Fieldbus-Gateway
Brand:
DEUTSCHMANN AUTOMATION
| Category:
Gateway
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Information on CE Marking of the Module
8
EU Directive EMC
8
Scope of Application
8
Note Installation Guidelines
8
Installation of the Unit
8
Working on Switch Cabinets
8
2 Information for the Machine Manufacturers
9
Introduction
9
EU Machinery Directive
9
3 Introduction
10
UNIGATE RS Software Flow-Chart
11
UNIGATE SC Software Flow Chart
12
UNIGATE Block Diagram
13
UNIGATE Application Diagram
13
4 Operation Modes of the Gateway
14
Configuration Mode (Config Mode)
14
Test Mode
14
Data Exchange Mode
15
5 RS-Interface
16
Framing Check - Only for UNIGATE RS
16
RS-Interface at the UNIGATE SC
16
Buffer Size at the UNIGATE SC
16
6 Mode of Operation of the System
17
General Explanation
17
Interfaces
17
Data Exchange
17
Possible Data Lengths
17
Run-Up Phase
18
The Trigger Byte - Only at UNIGATE RS
18
The Length Byte - Only at UNIGATE RS
18
7 Transparent Mode - Only at UNIGATE RS
19
8 Character-Delay-Time Mode - Only at UNIGATE RS
20
Receive Direction
20
9 Implemented Protocols in UNIGATE RS
21
Protocol ARCNET
21
Data Exchange
21
Broadcast
21
Data Structure
21
Trigger Byte
21
Length Byte
21
Arcnet-ID
21
Data Area
21
ARCNET Configuration
21
ARCNET-ID of the UNIGATE
22
Universal 232 Protocol
22
Data Structure
22
Fieldbus Parameters
22
RS232 Parameter Table
22
Start Character
22
Length 232
22
Data Area
23
Checksum
23
End Character
23
Communication Sequence
23
The 3964 R Protocol
23
Data Structure 3964R
24
Protocol Definitions
24
Data Communication
24
Initiation of Data Communication by the Low-Priority User
24
Conflicts
24
Timeout Times
24
Retries
24
Initiation of Data Communication by the High-Priority User
24
State of the 3964R Communication
25
The RK512-Protocol
25
Operating Sequence of the Data Transmission
26
Modbus-Rtu
26
Notes
26
UNIGATE as MODBUS-Master
26
Preparation
26
Data Structure
27
Communication Sequence
27
UNIGATE as MODBUS-Slave
27
Preparation
27
Data Structure
28
Communication Sequence
28
Status Report
28
UNIGATE as Modbus-ASCII Master
28
10 Generating a Script - Only for UNIGATE SC
29
What Is a Script
29
Memory Efficiency of the Programs
29
What Can You Do with a Script Device
29
Independence of Buses
29
Further Settings at the Gateway
29
The Use of the Protocol Developer
30
Accuracies of the Baud Rates at UNIGATE SC
30
Script Processing Times
31
11 Hardware Ports, Switches and Leds
32
Drawing of the Unit
32
Model UNIGATE RS / SC 232/485-Profibusdp
32
Model UNIGATE RS / SC 232/422-Profibusdp
33
Configuration of the UNIGATE RS
33
Configuration of the UNIGATE SC
33
Profibus
34
Rs232/Rs485/Rs422
34
Connectors
35
Connector to the External Device (RS-Interface)
35
Profibusdp Connector
36
Power Supply
36
Shield Terminal Lead
36
Leds
36
LED "Bus Error
37
LED "Bus Power
37
LED "Bus State
37
LED "Power
37
LED "State
37
Leds "Error No. / Select ID" at UNIGATE RS
37
Switches
37
Rotary Coding Switch (Profibus ID)
37
Slide Switch Termination Profibus
38
Rotary Coding Switches S4 + S5 (RS485 ID)
38
Slide Switch (RS485/RS232 Interface)
38
Slide Switch (RS485/RS422 Termination)
38
Special Features of the Debug Version
38
The Debug Cable for UNIGATE SC
38
12 Error Handling
39
Error Handling at UNIGATE RS
39
Error Handling at UNIGATE SC
39
13 Housing Variations
41
Main Operational Fields for Housings
41
Mounting Instruction
41
14 Installation Guidelines
43
Installation of the Module
43
Mounting
43
Removal
43
Wiring
43
Connection Systems
43
Profibusdp Communication Interface
44
Bus Line with Copper Cable
44
Power Supply
44
Shield Connection
44
Equipotential Bonding Connection
44
Line Routing, Shield and Measures to Combat Interference Voltage
44
General Information on Line Routing
44
Shielding of Lines
45
15 Profibusdp
47
Desription of the DPV1-/DPV2-Functions
47
Dpv1
47
Dpv2
47
Representation of the Data in Profibusdp
47
Configuration Telegram
48
Diagnosis
48
Diagnosis in DPV1
50
Data Exchange
51
16 Technical Data
52
Device Data
52
Interface Data
54
Housing Data
55
17 Commissioning Guide
56
Note
56
Components
56
Installation
56
Dimensional Drawing DIN-Rail Mounting
56
Commissioning
56
Setting the Profibus Address
56
Profibus Connection
57
Connection to the Process Device
57
Connecting the Supply Voltage
57
Shield Connection
57
Project Planning
57
Literature
57
18 Servicing
58
Returning a Device
58
Downloading PC Software and GSD Files Etc
58
19 Annex
59
Explanations of the Abbreviations
59
Hexadecimal Table
60
20 Drilling Templates
61
Aluminium Housing
61
High-Grade Steel Housing
62
Polycarbonate Housing
63
21 Declaration of Conformity and Certificates
64
EG Certificate of Conformance
64
Certificate Germanischer Lloyd
65
Advertisement
DEUTSCHMANN AUTOMATION UNIGATE SC232/485 Instruction Manual (50 pages)
Universal Fieldbus-Gateway
Brand:
DEUTSCHMANN AUTOMATION
| Category:
Gateway
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Information on CE Marking of the Module
8
EU Directive EMC
8
Scope of Application
8
Note Installation Guidelines
8
Installation of the Unit
8
Working on Switch Cabinets
8
2 Information for the Machine Manufacturer
9
Introduction
9
EU Machinery Directive
9
3 Introduction
10
Difference in the Hardware Version
10
4 General Facts on UNIGATE Lonworks
11
Nodes
11
Network Variables (Nvts)
11
Implementing the Network Variables into the UNIGATE-Lonworks
12
Installation
12
Technical Data (Characteristics) for Lonworks
12
UNIGATE SC Software Flow-Chart
13
UNIGATE Block Diagram
14
UNIGATE Application Diagram
14
5 Operation Modes of the Gateway
15
Configuration Mode (Config Mode)
15
Test Mode
16
Data Exchange Mode
16
6 RS-Interface
17
RS-Interface at the UNIGATE SC
17
7 Mode of Operation of the System
18
General Explanation
18
Interfaces
18
Data Exchange
18
Possible Network Variables and Their Data Lengths
18
Run-Up Phase
18
8 Generating a Script - for UNIGATE SC
19
What Is a Script
19
Memory Efficiency of the Programs
19
What Can You Do with a Script Device
19
Independence of Buses
19
Further Settings at the Gateway
19
The Use of the Protocol Developer
20
Accuracies of the Baud Rates at UNIGATE SC
20
Script Processing Times
21
9 Hardware Ports, Switches and Leds
22
Drawing of the Unit
22
Model UNIGATE SC232/485-Lonworks (UG 512)
22
Model UNIGATE SC232/422-Lonworks (UG 512)
22
Model UNIGATE SC232/485-Lonworks S (UG 62)
23
Model UNIGATE SC232/422-Lonworks S (UG 62)
23
Configuration of the UNIGATE SC
23
Lonworks
24
Rs232/Rs485/Rs422
24
Connectors
24
Connector to the External Device (RS-Interface)
24
Lonworks-Connector
25
Debug Plug
25
Power Supply
26
Shield Terminal Lead
26
Leds
26
LED "Service
26
LED "Bus State
26
LED "Power
26
LED "State
27
Leds "Error No. / Select ID" at UNIGATE RS
27
Switches
27
Sensor "Service
27
Rotary Coding Switches S4 + S5 (RS485 ID)
27
Slide Switch (RS485/RS232 Interface)
27
Slide Switch (RS485/RS422 Termination)
27
10 UNIGATE SC - Debug
28
The Debug Cable for UNIGATE SC
28
Developerkit
29
Quick Start
29
11 Error Handling
30
12 Housing Variations
31
Main Operational Fields for Housings
31
Mounting Instruction
31
13 Installation Guidelines
33
Installation of the Module
33
Mounting
33
Removal
33
Wiring
33
Connection Systems
33
Lonworks Communication Interface
34
Bus Line with Copper Cable
34
Power Supply
34
Shield Connection
34
Equipotential Bonding Connection
34
Line Routing, Shield and Measures to Combat Interference Voltage
34
General Information on Line Routing
34
Shielding of Lines
35
14 Representation of the Data in Lonworks
37
Network Variables (Nvts)
37
Determination of a LON-Gateway's Update Time
37
15 Technical Data
39
Device Data
39
Interface Data
40
Housing Data
41
16 Commissioning Guide
42
Note
42
Components
42
Installation
42
Dimensional Drawing DIN-Rail Mounting
42
Commissioning
42
Lonworks Connection
42
Connecting the Process Device
43
Connecting the Supply Voltage
43
Shield Connection
43
Project Planning
43
Literature
43
17 Servicing
44
Returning a Device
44
Downloading PC Software and GSD Files Etc
44
18 Annex
45
Explanations of the Abbreviations
45
Hexadecimal Table
46
19 Drilling Templates
47
Aluminium Housing
47
High-Grade Steel Housing
48
Polycarbonate Housing
49
DEUTSCHMANN AUTOMATION UNIGATE SC232/485 Instruction Manual (42 pages)
Universal Fieldbus-Gateway Fast Ethernet
Brand:
DEUTSCHMANN AUTOMATION
| Category:
Gateway
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Information on CE Marking of the Module
8
EU Directive EMC
8
Scope of Application
8
Note Installation Guidelines
8
Installation of the Unit
8
Working on Switch Cabinets
8
2 Information for the Machine Manufacturer
9
Introduction
9
EU Machinery Directive 89/392/EEC
9
3 Introduction
10
UNIGATE SC-Fast Ethernet Software Flow Chart
11
UNIGATE Application Diagram
12
4 RS-Interface
13
RS-Interface at the UNIGATE SC-Fast Ethernet
13
5 Operation Modes of the Gateway
14
Configuration Mode (Config Mode)
14
Test Mode
14
Data Exchange Mode
15
6 Mode of Operation of the System
16
General Explanation
16
Interfaces
16
Data Exchange
16
Possible Data Lengths
16
Run-Up Phase
16
7 Generating a Script - Only for UNIGATE SC-Fast Ethernet
17
What Is a Script
17
Memory Efficiency of the Programs
17
What Can You Do with a Script Device
17
Independence of Buses
17
Further Settings at the UNIGATE SC-Fast Ethernet
18
The Use of the Protocol Developer
18
Accuracies of the Baud Rates at UNIGATE SC
18
Script Processing Times
19
8 Hardware Ports, Switches and Leds
20
Drawing of the Unit
20
Model UNIGATE SC232/485-Fast Ethernet
20
Model UNIGATE SC232/422-Fast Ethernet
21
Configuration of the UNIGATE SC-Fast Ethernet
21
Ethernet
21
Connectors
22
Connector to the External Device (RS-Interface)
22
Ethernet 10/100BASE-T-Connection RJ45-Plug Connector
23
Power Supply
23
Shield Terminal Lead
23
Leds
23
LED "Bus State
23
LED "Bus Link
23
LED "Full Duplex
24
Led "10 Mb
24
Led "100 Mb
24
LED "Collision
24
LED "Power
24
LED "State
24
Leds "Error No. / Select ID" at UNIGATE SC-Fast Ethernet
24
Switches
24
Rotary Coding Switches S4 + S5 (RS485 ID)
24
Slide Switch (RS485/RS232 Interface)
24
Slide Switch (RS485/RS422 Termination)
25
9 Error Handling at UNIGATE SC-Fast Ethernet
26
10 Installation Guidelines
27
Installation of the Module
27
Mounting
27
Removal
27
Wiring
27
Connection Systems
27
Ethernet Communication Interface
28
Bus Line with Copper Cable
28
Power Supply
28
Shield Connection
28
Equipotential Bonding Connection
28
Line Routing, Shield and Measures to Combat Interference Voltage
28
General Information on Line Routing
28
Shielding of Lines
29
11 Representation of the Data in Ethernet-TCP/IP
31
Network-Addresses, Network-Connections
31
TCP-Connection Setup
31
Data Exchange
31
TCP or UDP
31
Data Exchange Mode
31
Direct Data Exchange
31
Modbus-Tcp
31
E-Mail
32
Server
32
Webserver
32
FTP-Server
32
File System
33
12 Technical Data
34
Device Data
34
Interface Data
36
13 Commissioning Guide
37
Note
37
Components
37
Installation
37
Dimensional Drawing DIN-Rail Mounting
37
Commissioning
37
Ethernet Connection
37
Connection of the Process Device
37
Connecting the Supply Voltage
38
Shield Connection
38
Project Planning
38
Literature
38
14 Servicing
39
Returning a Device
39
Downloading PC Software and GSD Files Etc
39
15 Annex
40
Explanations of the Abbreviations
40
Hexadecimal Table
41
Advertisement
Advertisement
Related Products
DEUTSCHMANN AUTOMATION UNIGATE SC232/422
DEUTSCHMANN AUTOMATION UNIGATE CM - PROFINET 2Port
DEUTSCHMANN AUTOMATION UNIGATE CL
DEUTSCHMANN AUTOMATION UNIGATE MB EtherCAT
DEUTSCHMANN AUTOMATION UNIGATE MB EtherNet/IP 2Port
DEUTSCHMANN AUTOMATION UNIGATE CANopen-ProfibusDP
DEUTSCHMANN AUTOMATION UNIGATE MB - MPI
DEUTSCHMANN AUTOMATION UNIGATE CL-Fast Ethernet
DEUTSCHMANN AUTOMATION UNIGATE IC-RS
DEUTSCHMANN AUTOMATION UNIGATE CL ProfibusDP
DEUTSCHMANN AUTOMATION Categories
Gateway
Microcontrollers
Controller
Network Router
Switch
More DEUTSCHMANN AUTOMATION Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL