Sign In
Upload
Manuals
Brands
Bartington Manuals
Measuring Instruments
MS2
Bartington MS2 Manuals
Manuals and User Guides for Bartington MS2. We have
1
Bartington MS2 manual available for free PDF download: Operation Manual
Bartington MS2 Operation Manual (82 pages)
Magnetic Susceptibility System
Brand:
Bartington
| Category:
Measuring Instruments
| Size: 8.41 MB
Table of Contents
Table of Contents
2
List of Figures
6
1 About this Manual
7
Symbols Glossary
7
2 Safe Use
7
3 Introduction
8
4 General Information
9
Measuring Magnetic Susceptibility
9
The Sensors
9
Operating Environment Considerations
10
Software
11
SI and CGS Units
12
Range Selection
12
Calibration
12
5 MS2 Meter
13
Front Panel Controls
13
Figure 1A. MS2 Meter, Front Panel
13
MS2 Meter Rear Panel
14
Rear Panel
14
Connecting a Sensor
14
Figure 1B. MS2 Meter, Rear Panel
14
Taking Measurements
15
Serial Interface
16
Internal Batteries
17
Figure 2. Replacing the MS2 Battery
18
Figure 3. Screws in the Base of the MS2 Meter
18
Figure 4. Double-Sided Insulation Foam
19
Data Transmission
20
Power Supply Accessories
21
6 MS2B Dual Frequency Sensor
22
General Description
22
Figure 5. MS2B Dual Frequency Sensor
22
Dual Frequency Measurements
23
Single Frequency Measurements
23
Setting up the Sensor
23
Preparation of Samples
25
Sample Holder Effects
25
Mass and Volume Specific Measurements
26
Taking Measurements
26
Calibration Notes
27
7 MS2C Core Scanning Sensor
28
General Description
28
Figure 6. MS2C Core Scanning Sensor
28
Operating Instructions
29
8 MS2E High Resolution Surface Scanning Sensor
30
General Description
30
Characteristics
30
Figure 7. MS2E High Resolution Surface Scanning Sensor
30
Figure 8. MS2E Response Characteristics
31
Figure 9. MS2E Calibration Sample: Correct Orientation
32
Operating Instructions
33
Care of Sensor
34
Figure 10. Using a Non-Magnetic Ruler with MS2E Sensor
34
9 MS2 Probe Handle for Use with Probes Type MS2D and MS2F
35
General Description
35
Figure 11. MS2 Probe Handle for Use with Probes Type MS2D and MS2F
35
10 MS2D Probe
36
General Description
36
Figure 12. MS2D Probe
36
Calibration Notes
37
11 MS2F Probe
37
General Description
37
Figure 13. MS2F Probe
37
Operating Instructions
38
Figure 14. Relative Variation in Sensitivity Around the MS2F Probe
38
12 MS2G Single Frequency Sensor
39
General Description
39
Figure 15. MS2G Single Frequency Sensor
39
Setting up
40
Sample Height Adjustment
40
Calibration
40
Taking Measurements
41
13 MS2H Down-Hole Probe
42
General Description
42
Figure 16. MS2H Down-Hole Probe
42
MS2H Equipment List
43
Operating Procedure
43
Checking Calibration
46
Scaling Factors
47
14 MS2K High Stability Surface Scanning Sensor
47
Figure 17. MS2K High Stability Surface Scanning Sensor
47
General Description
48
Characteristics
48
Operating Instructions
49
Figure 18. MS2K Depth Response
49
15 MS2/MS3 Susceptibility/Temperature System
51
MS2/MS3 Susceptibility Temperature System Cables
51
16 MS2W Water Jacketed Sensor
52
Figure 19. MS2W Water Jacketed Sensor
52
Calibration Note
53
17 MS2WF Furnace Sensor
53
Figure 20. MS2WF Furnace Sensor
53
Operation
54
Construction
55
Pt/Pt.rh Type 'S' Thermocouple
55
18 Maintenance of MS2WF Furnace
56
Preparation of Plugs
56
Furnace Outer Insulation
56
Thermocouple Installation
57
19 MS2WFP Power Supply/Temperature Controller
58
Figure 21. MS2WFP Power Supply/Temperature Controller
58
Internal Power Distribution
59
Temperature Control
59
RS-232 Buffer
59
Data Format
60
20 Operating Instructions for Susceptibility/Temperature System
60
Figure 22. Susceptibility/Temperature System
60
Setting up the Equipment
61
Figure 23. X/T Equipment
61
Figure 24. MS2WFP Connections
61
Figure 25. MS2WFP Outline Drawing and Mains Voltage Selection
62
Figure 26. MS2WFP Mains Voltage Selector Switch
63
Figure 27. Water Supply Connections
63
Figure 28. Water Cooling System for Susceptibility/Temperature System
64
Connection to a Computer (Geolab for Windows Software)
65
Figure 29. Setting MS3 to Mode B in Bartsoft
65
Sensor Orientation
66
Figure 30. Mounting the MS2W on the MS2WF
66
Sample Insertion
67
High Temperature Measurements
67
Figure 31. Using Tweezers to Insert Crucible into MS2W
67
Figure 32. Plug Inserted above Crucible
67
Figure 33. Thermocouple Selection Switch
68
Figure 34. MS2WFP Control Panel
68
Thermal Gradients
69
Low Temperature Measurements
70
Geolab
70
Figure 35. Connection for T Type Thermocouple
70
21 Troubleshooting
71
No Push-Button Operation
71
Large Variations in Measured Values
71
Serial Communications Problems
71
22 Storage and Transport
72
23 Disposal
73
Waste Electrical and Electronic Equipment (WEEE) Regulations
73
Appendix 1. Magnetic Susceptibility of Common Rocks
74
Figure A1.1 Magnetic Susceptibility of Common Rocks
74
Appendix 2. Calibration Graphs for MS2C Sensor
75
Figure A2.1. Relative Response to Varying Core Diameter Within MS2C Sensor
75
Figure A2.2. Thin Section Response of MS2C Sensor
76
Appendix 3. Anisotropy of Magnetic Susceptibility Measurements (AMS)
77
A3.1. Installation of the AMS Adapter
77
Figure A3.1. Changing the MS2B Platen
77
Appendix 4. Adjusting MS2B the Platen Height
79
Appendix 5. Calculating Magnetic Susceptibility
80
Notes
81
Advertisement
Advertisement
Related Products
Bartington Mag-01
Bartington Mag-01H
Bartington MS3
Bartington Mag628
Bartington Mag669
Bartington Mag629
Bartington Mag613
Bartington Mag648
Bartington Mag649
Bartington Mag592
Bartington Categories
Measuring Instruments
Accessories
Power Supply
Amplifier
Control Unit
More Bartington Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL