Drain Pan and Light Shield Removal
Drain Pan
SERVICE INSTRUCTIONS
OPERATION CONDITIONS AND PRESSURES
With room ambient temperature of +80
Suction pressure – 5 to 9 psig.
Head pressure – 210 to 260 psig.
Typical operating pressures for a properly charged unit operating at 0°F or lower box temperature, check
pressures immediately before normal off cycle expect a tolerance of ± 5 psig high side, and ±1 psig low side.
To remove the drain pan, remove screws along the front
Light Shield
face of the drain pan. Lift the rear of the pan up and out
of the drain trough. Slide pan towards you and out.
Reverse procedure to install.
To remove the light shield, remove screws along the front
face of the light shield. Pull the light shield towards you
and out. Reverse procedure to reinstall.
o
F and cold cabinet (unit cycling on control):
11