  • Page 1 Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988 PN 071-90000 Rev 03/06/08...
  • Page 3: Table Of Contents

    INTRODUCTION………………………………….……………………………………………………………………4 STORE CONDITIONS / LOCATION..………….…..………………………………………………………………..4 WARNING LABELS AND SAFETY INSTRUCTIONS………..…..……………………………………………… 5 PRE-INSTALLATION INSTRUCTIONS………………………..…..………………………………….…………… 6 Inspection for ShippingDamage……………………………………………………………….…………… 6 INSTALLATION INSTRUCTIONS………………………………………………………………………………….. 6 General Instructions…………………………………………………………………………………………. 6 Thermometer Installation…………………………………………………………………………………….6 Condensate Evaporator...……………………………………………………………………………………8 Power Toggle Switch…...…………………………………………………………………………………… 8 Electrical……..…………………………………………………………………………..…………………….8 STARTING PROCEDURE…………………………………………………………………………………………….8 FINAL CHECK LIST…………………………………………………………………………………….……………..8 LOADING………………………………………………………………………………………………………………..9 CLEANING……………………………………………………………………………………………………………...9 SERVICE INSTRUCTIONS (Trouble Shooting Guide)………………………….……………………………….9 MASTER-BILT PART NUMBERS……………………………………………………………………………………9 ACCESSORIES LIST………………………………………………………………………………………………….10...
  • Page 4: Introduction

    INTRODUCTION Thank you for purchasing a Master-Bilt cabinet. This manual contains important instructions for installing, using and servicing a Master-Bilt MPM/QMPM series open air case. Read all these documents carefully before installing or servicing your equipment. This manual should be left in the care of the store owner or manager.
  • Page 5: Warning Labels And Safety Instructions

    The portion of this manual covering refrigeration and electrical components contains technical instructions intended only for persons qualified to perform refrigeration and electrical work. This manual cannot cover every installation, use or service situation. If you need additional information, call or write us: Customer Service Department Master-Bilt Products 908 Highway 15 North...
  • Page 6: Pre-Installation Instructions

    PRE-INSTALLATION INSTRUCTIONS INSPECTION FOR SHIPPING DAMAGE You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage is noted to shipping crates or cartons or if a shortage is found, note this on the bill of lading (all copies) prior to signing.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS GENERAL INSTRUCTIONS 1. Be sure the equipment is properly installed by competent service people. 2. Keep the equipment clean and sanitary so it will meet your local sanitation codes. Wipe up all spills,clean with water and a mild detergent, then rinse with clean water. A reservoir is provided to contain interior spills. Peridocially inspect reservoir and clean as needed.
  • Page 8: Condensate Evaporator

    CONDENSATE EVAPORATOR The MPM/QMPM is designed to operate in an environment of 75° ambient and 55% relative humidity. When the conditions are applicable for condensation such as high temperature and high humidity, a large capacity condensate evaporator has been installed in the MPM/QMPM to ensure proper evaporation. POWER TOGGLE SWITCH The toggle switch turns the power ON or OFF and is accessible through a slot at the back of the MPM/QMPM- 36 and MPM/QMPM-48 cabinet.
  • Page 9: Loading

    LOADING Do not place product in the case until 6 hours after it is started. Stock cases as quickly as possible, exposing only small quantities to store temperatures for short periods of time. It is important to keep stock rotated properly so that older stock does not accumulate.
  • Page 10: Master-Bilt Part Numbers

    17-09120 17-09140 17-09140 03-14234 01-01474 09-09309 09-09307 07-13102 07-13103 15-01184 15-01184 13-00685 13-00685 21-00577 21-00577 21-00312 21-01218 19-13092 19-13092 19-00819 19-00819 19-01090 19-01090 MPM-72 QMPM-72 17-09130 17-09131 17-09140 01-01477 09-09185 07-13106 15-01184 13-00685 09-09548 21-00577 19-13092 19-00819 SHIP WT. LB/KG...
  • Page 11 A075-11140 Set of 4, 3" dia. for QMPM/MPM-36 and QMPM/MPM-48 A076-11140 Set of 6, 3" dia. for QMPM/MPM-72 SANDWICH RACKS - WELDED WIRE, CHROME PLATED 33-01450 16" L for QMPM and MPM models (Max. number of racks per model: -36 size: 2, -48 size: 3, -72 size: 4)
  • Page 12: Sale And Disposal

    SALE AND DISPOSAL OWNER RESPONSIBILITY If you sell or give away your Master-Bilt cabinet you must make sure that all safety labels and the Installation - Service Manual are included with it. If you need replacement labels or manuals, Master-Bilt will provide them free. Contact the customer service department at Master-Bilt at (800) 684-8988.