Chapter 6
Cajun Campus CLI – Layer 2
Monitors ifEntry.1.1026 every 30 seconds
Requested # of time intervals, ie buckets, is 20
Granted # of time intervals, ie buckets, is 20
Sample # 1 began measuring at 2:53:9
Received 62545 octets, 642 packets,
391 broadcast and 145 multicast packets,
0 undersize and 0 oversize packets,
0 fragments and 0 jabbers,
0 CRC alignment errors and 0 collisions,
# of dropped packet events (due to a lack of resources): 0
Network utilization is estimated at 0

Show rmon alarm Command

This command shows the parameters set for a specific alarm entry that was set
using the rmon alarm command on Page 90 or using the Cajun P330 Device
Manager.
The syntax for this command is:
show rmon alarm [<Alarm Index>]
Example:
Cajun_P330-N> show rmon alarm 1026
alarm
alarm 1026 is active, owned by amir
Monitors ifEntry.1.1026 every 60 seconds
Taking delta samples, last value was 1712
Rising threshold is 10000, assigned to event # 1054
Falling threshold is 10, assigned to event # 1054
On startup enable rising or_falling alarms

Show rmon event Command

This command shows the parameters of an Event entry defined by the rmon event
command on Page 91 or using the Cajun P330 Device Manager.
The syntax for this command is:
show rmon event [<Event Index>]
Example:
Cajun_P330-N> show rmon event 1054
event