GAS SPECIFICATIONS

• Consult your local Broaster Company
representative for gas conversions and
installations exceeding 2000 feet above
sea level.
• Gas Pressure and Orifice Size:
Manifold Gas Pressure:
NAT - On HIGH = 4.5" W.C.
LP - On HIGH = 8" W.C.
Burner Orifice Size:
NAT - #49 P/N 06783
LP - #56 P/N 06972
LOW Fire Orifice Size:
NAT - #24 P/N 14144
LP - #31 P/N14145

Connecting:

• A 1/2" pipe is located in the rear for gas
connection. Connect unit to 3/4" gas
supply line using adapter included with
your unit.
• Gas piping should conform to NFPA #54
or national, state, and local codes.
1. Turn POWER ON switch OFF.
2. After unit is installed in its permanent
location, turn gas shut-off valve ON.
Check all connections and pipes with a
soap and water solution. Bubbles indi-
cate a gas leak.
Manual #13799 5/97

ELECTRICAL SPECIFICATIONS

WARNING: Electrical Grounding
Instructions - This unit is equipped
with a three-prong (grounding) plug for your
protection against shock hazard and should
be plugged directly into a properly grounded
three-prong receptacle. DO NOT cut or
remove grounding prong from this plug.
• When installed, the unit must be electri-
cally grounded in accordance with local
codes, or in the absence of local codes,
with the National Electrical Code, ANSI/
NFPA 70.
• Canada: When installed, the unit must
be electrically grounded in accordance
with local codes, or in the absence of
local codes, with the Canadian Electrical
Code, CSA C22.2.
• The model 2000 Broiler is 1 20VAC,
1.25amp, 60Hz, grounded.
• When installing or servicing the unit,
always check the data plate located on
the inside of right hand side panel to
make certain proper parts are used and
the correct service rendered. DO NOT
apply a voltage to this unit other than
that shown on the data plate. If in doubt,
consult your local power company.
Connecting:
1. Turn POWER ON switch OFF.
2. After unit is installed in its permanent
location, plug in main power supply
cord attached to your unit.
3 - 4
Replace 8/97