Installation Information - Panasonic CS-A181KE Service Manual

Room air conditioners
Table of Contents

Advertisement

Installation Information

Indoor / Outdoor unit installation diagram
Length of power supply cord
about 1 m
about 2 m
< <
<
5 cm or
more
Insulation of piping connection
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Piping direction
Right
Right
<
rear
Right bottom
Air purifying filter 8
(Left and right are identical)
Carry out insallation
after checking for gas
leaks.
After securing with
three of the vinyl
tape 3, wrap with
vinyl tape 4.
Vinyl tape 3
(Front side)
Left
Left
rear
Left bottom
Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Putty (Gum Type Sealer) (*)
Bend the pipe as closely on the
wall as possible, but be careful
that it doesn't break.
Vinyl tape (Wide) (*)
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove the air filters
Vinyl tape
and pour water into the heat
4
exchanger.
Saddle (*)
Connecting cable
(3-CORE WIRE/2.5 mm
Locally approved cable.
Additional drain hose (*)
1/4" Liquid side piping (*)
Gas side piping 1/2" or 5/8" (*)
Vinyl tape (*)
(Narrow)
– 24 –
CS-A181KE
Attention not to bend up drain hose
Installation parts you must
purchase (*)
2
)