Panasonic CS-A181KE Service Manual page 15

Room air conditioners
Table of Contents

Advertisement

Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
Indoor
Fan
Comp.
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
Cooling Operation Time Diagram
Intake Air
Temperature
Set Temp.
Outdoor Air
Temperature
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
4 Way Valve
2 Way Valve (A241K)
<Description of operation>
d – g
:
Time Delay Safety Control (waiting for 3 minutes)
g – h
:
60 sec. Forced Operation
h – o
:
7 min. Time Saved Control
q – t
:
Anti Freezing Control
v – y
:
Outdoor Fan Control
. .
. .
1
SLo
stop
stop
40"
30"
ON
a b c d e f g h i j k l m n o p q r s t u v w x y z
Comp.
ON
1.5˚C
Comp.
OFF
31˚C
29˚C
1'
3'
SLo
SLo
SLo
stop
stop
20"
160"
40"
30"
OFF
ON
Indoor
10°C
Heat
Exchanger
Temp.
2°C
1'
7'
1'
4'
Hi
– 14 –
CS-A181KE
. .
. .
2
Operation
Stop
Hi
Hi Lo Lo Lo Hi

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-a241keCu-a241keCu-a181ke