Precor P10 Operating And Maintaining page 30

Hide thumbs Also See for P10:
Table of Contents

Advertisement

28
The following table contains a list of events detectable by the
software.
Table 4. Event log numbers and descriptions
Event
Number
00
02
03
05
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Description of Event
Upper PCA memory location event
RAM location event
EEPROM checksum event
Depressed key at power up
Lower PCA memory test event
Line Frequency out of acceptable range
Watchdog (Upper PCA) low voltage power
Watchdog (Lower PCA) low voltage power
Fan at incorrect speed (version 1 treadmills)
Fan fail (Lower PCA)
AC input voltage too high
AC input voltage too low
Dynamic break resistor thermal trip (treadmill only)
Dynamic break resistor thermal switch open (treadmill
only)
Power factor corrector malfunction (treadmill only)
Motor will not start, or no motor movement was
detected (treadmills only); too many maximum power
requests in one second (other equipment)
Too many maximum consecutive power requests
No motor pulses at start up
Motor pulses missing after start up
Reduce speed requested, speed is not reducing
Lower drive hardware error (treadmill only)
Motor pulse width incorrect
Too much drive motor current
Temperature too high
Excessive AC input current
Communications event lower board to upper board
Incorrect Communications event upper board to lower
board
Operating and Maintaining the P10 Console

Advertisement

Table of Contents
loading

Table of Contents