Setting The System Option Modes; Configuring The Fibre Channel Ports - HP XP7 Configuration Manual

Hide thumbs Also See for XP7:
Table of Contents

Advertisement

Figure 5 Set UUID window (OpenVMS)
6.
Enter a UUID in UUID in the Set UUID window. When a OpenVMS server host is used, a UUID
can consist of the numerical value between 1 to 32,767.
7.
Click OK to close the Set UUID window.
8.
Click Apply in the LUN Manager window. A message appears asking whether to apply the
setting to the storage system.
9.
Click OK to close the message. The settings are applied to the storage system and the UUID
is set.
CAUTION:
to OpenVMS hosts. Do not select a mode other than 05 for OpenVMS. Changing a host mode
after the host has been connected is disruptive and requires the server to be rebooted.

Setting the system option modes

The HP service representative sets the system option mode(s) based on the operating system and
software configuration of the host. Notify your HP representative if you install storage agnostic
software (such as backup or cluster software) that might require specific settings.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using XP7 Command View Advanced Edition
Software or the XP7 Remote Web Console (shown). Select the settings for each port based on your
SAN topology. Use switch zoning if you connect different types of hosts to the array through the
same switch.
The correct host mode must be set for all new installations (newly connected ports)
Installing and configuring the disk array
45

Advertisement

Table of Contents