Electrical connection (208 V)
Voltage (default)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Voltage (convertible)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Electrical connection (240 V)
Voltage
(default)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection
Voltage (convertible)
Rated load
Fuse rating
Minimum cross-section
Length of electrical cord (UL 921) with plug
Electrical connection

Cold water connection

Max. temperature
Max. water hardness
Min. flow pressure
Min. flow pressure with extended water intake
Max. pressure
Throughput
Connection thread - on site (flat sealing)
Length of connection hose (supplied)
 
Installation plan PG 8056 
 
 
2 AC 208V 60 Hz
5.8 kW
2 × 30 A
3 × AWG 10
approx. 5' 7"
NEMA L6-30
3 AC 208V 60 Hz
5.8 kW
3 × 20 A
4 × AWG 12
approx. 5' 7"
NEMA L15-20
2 AC 240V 60 Hz
5.8 kW
2 × 30 A
3 × AWG 10
approx. 5' 7"
NEMA L6-30
3 AC 240V 60Hz
5.8 kW
3 × 20 A
4 × AWG 12
approx. 5' 7"
NEMA L15-20
68 °F
73 gpg
29 psi
5.8 psi
145 psi
2 gal/min
3/4" Male Garden Hose
Thread
(USA: 11.5 NH)
approx. 5' 7"
2 AC 208V 60 Hz
5.8 kW
2 × 30 A
3 × 5.2 mm²
approx. 1.7 m
NEMA L6-30
3 AC 208V 60 Hz
5.8 kW
3 × 20 A
4 × 3.3 mm²
approx. 1.7 m
NEMA L15-20
2 AC 240V 60 Hz
5.8 kW
2 × 30 A
3 × 5.2 mm²
approx. 1.7 m
NEMA L6-30
3 AC 240V 60Hz
5.8 kW
3 × 20 A
4 × 3.3 mm²
approx. 1.7 m
NEMA L15-20
20 °C
70 °d
200 kPa
40 kPa
1,000 kPa
7.5 l/min
3/4" Male Garden
Hose Thread
approx. 1.7 m