right:
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5 NC5
CTRL 12V
+12V
485 A/B
T+,T-,R+,R-
3.6.2 Alarm Input Port
Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
Use the same ground with that of DVR if you use external power to the alarm device.
3.6.3 Alarm Output Port
Provide external power to external alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
Control power output. For external alarm, you need to close the
device power to cancel the alarm.
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 communication port. They are used to control devices such as
decoder.
They are four-wire double duplex RS485 port
T+ T-: output wire
R+ R-: input wire
Figure 3-9