Extension Of The Connecting Cable; Terminator (2 Pce); Lon Communication Module; Appendix - Viessmann VITODENS 200-W Technical Manual

Gas condensing boilers 17.0 to 150.0 kw as multi boiler system up to 900.0 kw
Table of Contents

Advertisement

Control units
(cont.)

Extension of the connecting cable

■ Installation spacing 7 to 14 m:
– 2 connecting cables (7.0 m long)
Part no. 7143 495
– 1 LON coupling RJ45
Part no. 7143 496
■ Installation distance 14 to 900 m with plug-in connectors:
– 2 LON plug-in connectors
Part no. 7199 251
– 2-core cable:
CAT5, screened
or
Solid conductor AWG 26-22 / 0.13 mm
Conductor AWG 26-22 / 0.14 mm
7 4.5 mm - 8 mm

Terminator (2 pce)

Part no. 7143 497
For terminating the LON BUS at the first and last control unit.

LON communication module

PCB for exchanging data with the Vitotronic 200-H, Vitocom 100 type
LAN1, Vitocom 200 and for connecting to a higher ranking building
management system.

Appendix

6.1 Regulations / Directives

Regulations and Directives

The design and operational characteristics of the Vitodens gas con-
densing boilers from Viessmann meet the requirements of EN 297.
They are CE-designated.
They may be installed in sealed unvented heating systems with per-
missible flow temperatures (= safety temperatures) up to 100 ºC to
EN 12828. The maximum achievable flow temperature is approx.
15 K below the safety temperature.
Observe all standards and statutory requirements applicable to the
6
installation and operation of this system in your country.
Only qualified contractors should carry out the installation, the mains
gas and connection on the flue gas side, the commissioning and the
electrical connection as well as general maintenance and repair
work.
The installation of a condensing boiler may need to be notified to and
approved by your local gas supply utility.
EnEV
1st BImSchV
FeuVo
DIN 1986
DIN 1988
DIN 4753
DIN 18160
DIN 18380
DIN 57116
EN 677
EN 12828
EN 12831
EN 13384
DWA-A 251
DVGW G 260
DVGW G 600
DVGW G 688
VIESMANN
70
2
- 0.32 mm
2
,
2
- 0.36 mm
2
Energy Saving Ordinance
First regulation for the implementation of the German Immissions Act (regulation regarding small and me-
dium-sized combustion equipment)
Fire Regulations of the German Federal States
Drainage system materials
DHW pipe systems for properties
Water heaters and DHW systems for DHW and process water
Domestic chimneys
Heating systems and central DHW heating systems (VOB)
Electrical equipment for combustion systems
Gas condensing boilers
Heating systems in buildings – design of hot water heating systems
Heating systems in buildings – process for calculating the standard heat load
Flue systems – thermal and flow technical calculations
Introduction of condensate from gas and oil combustion systems [into public sewers]
Gas condition
Technical rules for gas installations (TRGI)
Gas consumption equipment, condensing technology
on-site
■ Installation distance 14 to 900 m with junction boxes:
– 2 connecting cables (7.0 m long)
Part no. 7143 495
– 2-core cable:
CAT5, screened
or
Solid conductor AWG 26-22 / 0.13 mm
Conductor AWG 26-22 / 0.14 mm
7 4.5 mm - 8 mm
on-site
– 2 LON sockets RJ45, CAT6
Part no. 7171 784
■ For installation in the Vitotronic 200
Part no. 7179 113
■ For installation into the Vitotronic 300-K
Part no. 7172 174
In some regions, permits may be required for the flue system and con-
densate drain into the public sewage system.
In some countries, the relevant flue gas inspector and water authorities
must be informed prior to commencing the installation.
We recommend that you carry out maintenance and cleaning proce-
dures annually. As part of the maintenance procedure, check the cor-
rect function of the entire system. Remedy any faults.
Condensing boilers must only be operated with specially designed,
tested and approved flue pipes.
Only authorised contractors may convert this boiler for use in countries
other than those stated on the type plate. That contractor must also
arrange the acceptance in accordance with the statutes of the relevant
country.
2
- 0.32 mm
2
,
2
- 0.36 mm
2
VITODENS 200-W

Advertisement

Table of Contents
loading

Table of Contents