Control units
(cont.)
Vitotronic
Type
Accessories
Extension EA1
Vitocom 100, type LAN1, in conjunction with Vitodata 100 and
Vitotrol App
Vitocom 100, type LAN1, in conjunction with Vitodata 100
Vitocom 100, type GSM
LON cable
LON coupling
LON plug-in connector
LON socket
Terminator
LON communication module

Vitotrol 100, type UTA

Part no. 7170 149
Room thermostat
■ With switching output (two-point output)
■ With analogue time switch
■ With adjustable individual day program
■ Standard switching times are factory-set (individually programma-
ble)
■ Shortest switching interval 15 minutes
Install the Vitotrol 100 in the main living room on an internal wall oppo-
site radiators, but not inside shelf units, recesses, immediately by a
door or a heat source (e.g. direct sunlight, fireplace, TV set, etc.).
Control unit connection:
3-core cable with a cross-section of 1.5 mm
230 V~.
3 4
1 5
5
0

Vitotrol 100, type UTDB

Part no. Z007 691
Room temperature controller
■ With switching output (two-point output)
■ With digital time switch
■ With individual and 7-day programs
■ Operation with user prompts:
– 3 preselected time programs, individually adjustable
– Constant manual mode with adjustable set room temperature
– Frost protection mode
– Holiday program
■ With selector keys for party and economy mode
Installation in the main living room on an internal wall opposite radia-
tors. Never install inside shelving units, in recesses, or immediately by
a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.).
Operation independent of mains power supply (two 1.5 V round alka-
line batteries, type LR6/AA, which run for approx.1.5 years).
Control unit connection:
2-core lead with a cross-section of 0.75 mm
VIESMANN
54
100
HC1B
x
x
Specification
Rated voltage
Rated breaking capacity of the con-
tact
IP rating
Permissible ambient temperature
– during operation
– during storage and transport
Set value setting range for standard
mode and reduced mode
Set room temperature in standby
mode
2
(without green/yellow) for
2
for 230 V~.
200
HO1B
x
x
x
x
x
x
x
x
x
x
230 V/50 Hz
6(1) A 250 V~
IP 20 to EN 60529
ensure through appropriate
design/installation
0 to +40 °C
–20 to +60 °C
10 to 30 °C
6 °C
8 0
300-K
MW2B
x
x
x
x
x
x
x
x
VITODENS 200-W