PLC TROUBLESHOOTING
SCREEN 8:
RINSE TANK
TEMPERATURES
SCREEN 9:
WASH CYCLE COUNT
The "Rinse Tank Temperatures" screen allows the user to see the temperature
readings in the top and bottom rinse tanks.
Not applicable for AVENGER LT-E Models.
A
B
C
D
1. Line C shows the current temperature reading of the top booster tank.
2. Line D shows the current temperature reading of the bottom booster tank.
The "Wash Cycle Count" screen allows the user to see the number of cycles since
the last complete tub drain and edit the number of cycles that perform before the
"flush" light activates.
A
B
C
D
1. Line C displays the number of cycles since the last "flush" or complete tub drain.
2. Line D shows the number of cycles that perform before the "flush" light activates.
• Press + or - to highlight line D.
• Press OK to enter highlight mode.
• Press + or - to make any adjustments needed.
* Flush Setpoint: 5 to 30
• Press OK to confirm adjustments.
• When flush light is activated, user should remove the standpipe and drain the tub.
Crouzet
RINSE TANK TEMPS:
TOP:
BOTTOM:
Crouzet
WASH CYCLE COUNT:
CURRENT COUNT:
FLUSH SETPOINT: 05