PLC TROUBLESHOOTING
SCREEN 2:
FAULTS
The "Faults" screen will be displayed when the operator has pressed "A" or "B" to cycle
through screens and is intended to show the technician any faults that have occurred.
A
B
C
D
Line C will show any fault observed from previous cycles. The faults will be identified as
1-6 and are detailed below (multiple faults may be active at the same time):
Fault 1: Indicates the horizontal float switch did not close during the initial fill.
• Open the door and check the water level. If low, turn machine off then
back on to start an additional fill cycle.
Fault 2*: Indicates the vertical float switch has activated and the machine is overfilled.
• To clear this fault verify the water level and remove the standpipe.
• Attempt to drain the machine by cycling power on then off.
• If the machine is not overfilled, manually trigger the float switch and verify
status of input on PLC.
Fault 3: Indicates the horizontal float switch opened for more than 5 seconds.
• Allow cycle to complete to determine if fault 3 clears.
• If not, open the door and verify the standpipe is fully seated, strainers are
in place, and water level is low.
Fault 4: Indicates Sanisure was active for the maximum wash cycle time.
• Verify incoming water meets minimum temperature and pressure specification.
• Adjustment of rinse tank differential set point may be needed (see screen #7).
• Not applicable for AVENGER LT-E Models.
Fault 5: Indicates fault 4 has been activated for 5 consecutive cycles.
• If fault #5 is active contact technical service for assistance.
• Not applicable for AVENGER LT-E Models.
Fault 6: Indicates the drain cycle has completed and the hortizonal float switch is still
active.
• Verify standpipe is removed prior to turning machine off.
• Verify water level. If high and standpipe is removed verify there are no
clogs in drain line.
* Faults 2 and 5 will prevent the unit from cycling.