PLC TROUBLESHOOTING
SCREEN 6:
TEMPERATURE
SETPOINTS
Screen 6 is the "Temperature Setpoints" screen and allows the user to edit the wash
tank, top rinse tank and bottom rinse tank temperatures.
A
B
C
D
1. Line C shows the wash tank temperature.
• Press + or - to highlight line B.
• Press OK to enter highlight mode.
• Press + or - to make any adjustments needed.
* HT-E Wash Tank Temperature: 155°F to 175°F (68°C to 79°C).
* LT-E Wash Tank Temperature: 115°F to 130°F (46°C to 54°C).
• Press OK to confirm adjustments.
2. Line D shows the rinse tank temperature.
• Press + or - to highlight line C.
• Press OK to enter highlight mode.
• Press + or - to make any adjustments needed.
* Rinse Tank Temperature: 170°F to 190°F (77°C to 88°C).
• Press OK to confirm adjustments.
Crouzet
TEMP SETPOINTS:
WASH:
RINSE: