U-Line 3018RGL User Manual page 51

Safety • installation & integration • operating instructions • maintenance • service 18" glass door refrigerator 3000 series
Hide thumbs Also See for 3018RGL:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
Relay Toggle
Up
Down
Relay toggle is used to manually switch the state of each
relay to test for proper operation. In addition to the AC
relays, DC outputs may also be toggled. Relay toggle can
also be used to force the unit into a particular state. For
example, to force a 3018 / 3045 into a cooling cycle
activate Comp, F1, and F3.
ID
Description
Mull
Mullion Heater (Not Used)
Cond
Fan (Not Used)
Def
Defrost Valve (Not Used)
LVLV
Left Valve (Not Used)
RVLV
Right Valve (Not Used)
Pan
Pan Heater (Not Used)
Comp
Compressor
F1
Evaporator Fan
F2
Evaporator Fan (Not Used)
F3
Condenser Fan
L1
Cabinet Lighting
L2
Cabinet Lighting (Not Used)
To access Relay Toggle:
1. Press
to select "Relay Toggle".
2. Press
.
3. Press
and
to scroll through each relay or DC
output.
4. Press
to toggle.
5. To exit the Relay Toggle menu, press
"Return to Menu" and press
Select
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF
Type
AC
AC
AC
AC
AC
AC
AC
DC
DC
DC
DC
DC
to select
to confirm.
CONVECTION COOLING
All 3000 series units are equipped with an advanced
convection cooling system. Convection cooling stabilizes
cabinet temperature, cools product faster and increases
energy efficiency.
Evaporator Fan
The evaporator fan is responsible for circulating warm air
from the refrigeration zone, past the evaporator and back
into the refrigerated zone.
The evaporator fan is factory set to have a 1 minute delay
at the beginning of a cooling cycle. This delay gives the
evaporator time to cool properly before warm air is passed
over it. The fan will continue to run for an additional 2
minutes at the end of a cooling cycle. Fan delay times can
be modified through the service menu.
Evaporator fan operation is also determined by door
switch state. If the door switch circuit opens the fan will
stop. When the door switch circuit is closed the fan will
either continue running with the cooling cycle, or if not
currently cooling, the fan will run for 1 minute to circulate
air and clear any condensation that may have appeared
on glass doors and shelves.
NOTE: If the unit is set to sabbath mode the evaporator
fan will no longer respond to the state of the door switch.
In order to operate efficiently the evaporator fan blade
and vents should be unobstructed and free of any dust
buildup.