MTU 8 V 2000 M40A Operating Instructions Manual page 68

Hide thumbs Also See for 8 V 2000 M40A:
Table of Contents

Advertisement

RAW WATER CIRCUIT (open circuit)
Number of cylinders
Raw water pump: Inlet pressure, min.
Raw water pump: Inlet pressure, max.
Pressure loss in external raw water system, max.
LUBE OIL SYSTEM
Number of cylinders
Lube-oil operating temperature before engine, from
Lube oil operating temperature before engine, to
Lube oil operating pressure before engine, from
Lube oil operating pressure before engine, to
FUEL SYSTEM
Number of cylinders
Fuel pressure at engine supply connection, min. (when engine is starting)
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
Fuel pressure at engine supply connection, max. (when engine is starting)
Fuel supply flow, max.
GENERAL OPERATING DATA
Number of cylinders
Firing speed, from
Firing speed, to
STARTING (electric)
Number of cylinders
Starter, rated voltage (standard design)
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders
Starting air pressure before starter motor, min.
Starting air pressure before starter motor, max.
68 | Product Summary | MS150031/03E 2011-10
16
L
bar
-0.2
L
bar
+0.5
L
bar
1.0
16
R
°C
80
R
°C
85
R
bar
6.0
R
bar
7.0
16
L
bar
-0.3
L
bar
-0.3
L
bar
+0.5
R
liter/min
4.2
16
R
rpm
100
R
rpm
120
16
R
V=
24
16
R
bar
24*
R
bar
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents