64 installation
INSTALLATION OF THE APPLIANCE
Underbench oven
Your underbench oven looks best when the control panel
is directly under the benchtop. An upper infill panel may
be added if the cooktop placed above the benchtop is too
deep. Refer to cooktop installation instructions for required
clearance between cooktop and oven.
IMPORTANT!
Note: Dimension'D'*
A requirement for all EVEPxxxx pyrolytic clean ovens and
Duo ovens – for proper ventilation there must be a gap
at the bottom rear of the cabinet. This can be a full width
opening 20mm deep.
Power point connection for the EVEP615SB and
EVEP618BB must be accessible with the appliance fully
installed. If the supply cord is damaged it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Cut-out dimensions
type of fit
A (width)
B (height)
C (depth)
Flush fit (mm)
600
600
581 min.
Proud fit (mm)
568
590
560 min.
561mm
596mm
Double oven Cut-out dimensions
type of fit
A (width)
B (height)
C (depth)
Flush fit (mm)
600
1086
581 min.
Proud fit (mm)
568
1078
560 min.
561mm
650mm
min.
mounting
596mm
holes 582mm
Pyrolytic underbench cut-out dimensions
type of fit
A (width) B (height)
C (depth)
Flush fit (mm)
600
600
561mm
596mm
Duo oven cut-out dimensions
type of fit
A (width) B (height)
C (depth)
Flush fit (mm)
600
893
561mm
D
650mm
min.
mounting
holes 582mm
mounting
holes 582mm
A

TECHNICAL SPECIFICATIONS

B
D*
C
581 min.
20
product dimensions
model
EVE611SA
EVE613SA
EVE614BA
EVE616BA
EVEP611SB
EVEP614BB
EVEP613SB
EVEP616BB
EVEP615SB
mounting
EVEP618BB
holes 582mm
EVE623SA
EVEP623SB
EVEP626BB
EVE633SA
D*
581 min.
20
Hard wiring details
1. Remove terminal cover plate from rear panel of
appliance.
A
2. Fit wires through hole in cover plate and make
B
connections to terminals.
C
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
min. 650mm
4. Replace cover plate onto rear panel.
Error codes
mounting holes
582mm
fit long screws
error code
description
provided
F01 or 01
Door lock sensor alarm
F02 or 02
Door lock actuator alarm
mounting holes
fit countersunk screws
with plastic spacers
provided
F04 or 04
Oven Probe (PT500) out
Oven Probe (PT500) too
F05 or 05
high temperature alarm
Board Temperature
25
Sensor (NTC) too high
temperature alarm
Board Temperature
26
Sensor (NTC) out of
range warning
Board Temperature
6
Sensor (NTC) out of
range alarm
F08 or 08
Communication alarm
Software compatibility
F09 or 09
code alarm
C1
Telescopic runners fitted
C3
Door open
EEPROM check sum
F03 or 03
alarm
EEPROM compatibility
F14 or 14
code alarm
561mm
min. 650mm
electrical
min. fuse rating
(h x w x d) mm
connection
597 x 596 x 573
230-240V/50Hz
16A
mounting holes
597 x 596 x 573
230-240V/50Hz
16A
583mm
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
596mm wide (all products)
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
597 x 596 x 573
230-240V/50Hz
16A
890 x 596 x 573
230-240V/50Hz
25A
890 x 596 x 573
230-240V/50Hz
25A
890 x 596 x 573
230-240V/50Hz
25A
1083 x 596 x 573
230-240V/50Hz
25A
561mm
mounting
holes
mounting holes
456mm
596mm
comment
This relates to a door lock failure which is only
associated with the Pyrolytic product
This relates to the temperature sensing probe
which may be out of tolerance, of range alarm
or have open/short circuit connections
This relates to the temperature of the
powerboard and/or the (NTC)
on the powerboard
This relates to an error in communication
between the powerboard and the IOI
controller. This can occur if the IOI controller is
connected while the powerboard is energised
This relates to a mismatch between
powerboard firmware version and the IOI
controller firmware version. Most likely caused
by an un-programmed powerboard
Only applies to Pyrolytic product
Only applies to Pyrolytic product
Relates to the controller
Relates to the controller
B
installation 65
C
mounting
holes
max. power rating
max. current rating
3.1kW
12.9A
mounting holes
3.1kW
12.9A
456mm
3.1kW
12.9A
596mm
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.5kW
12.9A
3.5kW
12.9A
5.3kW
22.1A
5.3kW
22.1A
5.3kW
22.1A
6.2kW
24.2A
Plastic clips
Plastic clip
securing points
fix
Check wiring/plugs or replace door lock
Replace probe
Cooling fan not working or replace
powerboard
Reset power. (Minimum of 20 sec.) or
check or replace data cable
Replace Powerboard
Remove both side racks and re-start
pyrolytic cycle
Close door and restart pyrolytic cycle
Replace Controller
Replace Controller