Technical Specifications - Electrolux EVE611SA User Manual

Hide thumbs Also See for EVE611SA:
Table of Contents

Advertisement

561mm
B

TECHNICAL SPECIFICATIONS

product dimensions
model
(h x w x d) mm
EVE611SA
597 x 596 x 573
596mm wide (all products)
EVE613SA
597 x 596 x 573
EVE614BA
597 x 596 x 573
EVE616BA
597 x 596 x 573
EVEP611SA
597 x 596 x 573
EVEP614BA
597 x 596 x 573
EVEP613SA
597 x 596 x 573
EVEP616BA
597 x 596 x 573
EVEP615SA
597 x 596 x 573
EVEP618BA
597 x 596 x 573
EVE623SA
890 x 596 x 573
EVE633SA
1083 x 596 x 573
Hard wiring details
561mm
1. Remove terminal cover plate from rear panel of
A
appliance.
B
2. Fit wires through hole in cover plate and make
C
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Error codes
596mm
error code
description
F01 or 01
Door lock sensor alarm
F02 or 02
Door lock actuator alarm
F04 or 04
Oven Probe (PT500) out
Oven Probe (PT500) too
F05 or 05
high temperature alarm
Board Temperature
25
Sensor (NTC) too high
temperature alarm
Board Temperature
26
Sensor (NTC) out of
range warning
Board Temperature
6
Sensor (NTC) out of
range alarm
F08 or 08
Communication alarm
Software compatibility
F09 or 09
code alarm
C1
Telescopic runners fitted
C3
Door open
EEPROm check sum
F03 or 03
alarm
EEPROm compatibility
F14 or 14
code alarm
mounting holes
583mm
electrical
connection
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
230-240V/50Hz
mounting
holes
mounting holes
456mm
comment
This relates to a door lock failure which is only
associated with the Pyrolytic product
This relates to the temperature sensing probe
which may be out of tolerance, of range alarm
or have open/short circuit connections
This relates to the temperature of the
powerboard and/or the (NTC)
on the powerboard
This relates to an error in communication
between the powerboard and the IOI
controller. This can occur if the IOI controller is
connected while the powerboard is energised
This relates to a mismatch between
powerboard firmware version and the IOI
controller firmware version. most likely caused
by an un-programmed powerboard
Only applies to Pyrolytic product
Only applies to Pyrolytic product
Relates to the controller
Relates to the controller
min. 650mm
min. fuse rating
max. power rating
16A
16A
16A
16A
16A
16A
16A
16A
16A
16A
25A
25A
fix
Check wiring/plugs or replace door lock
Replace probe
Cooling fan not working or replace
powerboard
Reset power. (minimum of 20 sec.) or
check or replace data cable
Replace Powerboard
Remove both side racks and re-start
pyrolytic cycle
Close door and restart pyrolytic cycle
Replace Controller
Replace Controller
installation 63
max. current rating
596mm
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
3.5kW
12.9A
3.5kW
12.9A
5.3kW
22.1A
6.2kW
24.2A
Plastic clips
Plastic clip
securing points
holes
mounting holes
456mm