HI P-Oil Filter Fifference
Cause
Oil pressure difference between
oil pressures before and after
filter too high.
MG Disengagement Fault
Cause
RCS message.
MG Eng Speed High/Low (Clutch)
Cause
RCS message.
MG Engagement Fault
Cause
RCS message.
MG Check Start Interlocks
Cause
Start conditions are not
fulfiulled.
RL 211+A001-A001
Cause
DIS not detected on redundant
bus
RL 211+A001-A010
Cause
LCU of LOP 1 (PIM No. 21.X
+A001-A010) not detected on
redundant CAN bus.
Corrective action
u Replace engine oil filter (→ Page 190).
Corrective action
u Contact Service.
• Have GCU solenoid checked and replaced, if required.
• Have GCU wiring checked and replaced, if required .
Corrective action
u Speed reduction
Corrective action
u Contact Service.
• Have GCU solenoid checked and replaced, if required.
• Have GCU wiring checked and replaced, if required .
Corrective action
u Check start conditions and fulfill if necessary.
Corrective action
1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Contact Service.
• Have DIS checked and replaced, if required.
Corrective action
1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Contact Service.
• Have MPU 23 of PIM No. 21.X+A001-A010 checked and
replaced, if required.