BEFORE CALLING
FOR SERVICE
_CHECK VENT indicator is
blinklng
This warning
light is
not a dryer failure and is
not covered by the dryer
warranty.
Contact a duct
cleaning service to set
up an appointment
to
have your exhaust system
cleaned and inspected.
The CHECK VENT
indicator remains active
(blinking)
after clearing
the restriction
in the vent-
ing.
iiiiiiiii i iiiii !iiiiiiiiii!!iiii_Yiiii_i_i_iii
ii_ii_:i
ii:i_i_ii_iiii_iiHiiiii iii/_!_i ii _'_
ii HI_ Y"
_iI _
Exhaust system is too long or has
too many turns/restrictions.
Partial blockage
of the ductwork
due to tint buildup or other
foreign object.
The appliance
has detected
a
restriction
in the external
dryer
venting.
After clearing
the restriction,
the
CHECK VENT system requires
multiple,
consecutive
cycles to
determine
that the performance
value has improved before the
CHECK VENT indicator
is reset.
Iiiiiiiiiiii!iiiii!i! i!!iiiiiiiii!iiIiii!i!i!iii iiii iiiiiii! H!iHi
i i iiilii!il liiliiii iiiiilHillli/!i
!ili!!liliiiliiii!!i!ii
Install a shorter or straighter
duct run. See the
Installation
Instructions for details.
Ductwork should be checked/cleaned
immediately.
Dryer can be used in this condition,
but drying
times will be longer and energy consumption
will
increase.
See the CHECK VENT INDICATOR
and CHECK
VENT OPERATION sections for details regarding
this function.
If the CHECK VENT indicator
remains active for
more than five cycles after the restriction
has been
cleared,
call for service.
L
Dryer will not turn on
Power cord is not properly
Make sure that the plug is securely plugged
into a
plugged
in.
grounded outlet matching the dryer's rating plate.
Dryer does not heat
Greasy or dirty spots an
clothes
House fuse is blown, circuit
breaker has tripped,
or power
outage has occurred.
House fuse is blown, circuit
breaker has tripped,
or power
outage has occurred.
Gas supply or service is turned off
(gas models only).
Clean and dirty clothes are being
dried together.
Clothes were not properly
cleaned
or rinsed before being placed
in
the dryer.
Heat settings, load size, or
dampness of clothing is not
consistent.
Drying time is not consls-
tent
Reset circuit breaker or replace fuse. Do not
increase fuse capacity.
If the problem
is a
circuit overload,
have it corrected
by a qualified
electrician.
Reset circuit breaker or replace fuse. Do not
increase fuse capacity.
If the problem
is a
circuit overload,
have it corrected
by a qualified
electrician.
NOTE: Due to the design of electric dryers, it is
possible for a circuit problem to allow an electric
dryer to run without heat.
Confirm that the house gas shutoff: and the dryer
gas shutoff valves are both fully open. Even if gas
is not supplied to the dryer, it will run and no error
codes will display. Verify that other gas appliances
in the home are working normally.
Only use your dryer to dry clean items. Soil from dirty
clothes can transfer to the clean clothes in the same or
later loads.
Stains on dried clothes could be stains that weren't
removed during the washing process. Make sure
that clothes are being completely
cleaned
or
rinsed according
to the instructions for your washer
and detergent.
Some difficult
soils may require pre-
treating
prior to washing.
The drying time for a load will vary depending
on
the type of heat used (electric, natural gas, or LP
gas), the size of the load, the type of fabrics, the
wetness of the clothes, and the condition
of the
exhaust duct and lint filter. Even an unbalanced
load in the washer can cause poor spinning,
resulting in wetter clothes which will take longer to
dry.