Cleaning; Cautions At The Maintenance Of Devices Connected To The Ups - Omron POWLI BU100XR2 Instruction Manual

Table of Contents

Advertisement

6. Maintenance and inspection

6-3 Cleaning

1. Cleaning of the UPS
Damp a soft cloth with water or detergent, squeezes it tightly, and wipes the UPS lightly.
Do not use chemicals such as thinner and benzene. (They cause deformation or discoloration.)
2. Removing dust from the AC Input Plug of the UPS
Turn off all the devices linked to the UPS and the UPS, and remove the AC Input Plug from a wall outlet
(commercial power).
Then, remove dust with a dry cloth and make the plugging again.
(For information on the connection, see "2. Installation and connector" on page 12.)
6-4 Cautions at the maintenance of devices
connected to the UPS
Before maintaining devices connected to the UPS, turn off the UPS and
remove the AC Input Plug from a wall outlet (commercial power).
● Even if you remove the AC Input Plug during the operation of the UPS, the backup function of
the UPS keeps feeding power through the power supply output receptacle of the UPS.
● In a case where the scheduled operation is ON and the AC Input Plug of the UPS is put in a
wall outlet (commercial power), the UPS starts feeding power at the starting time of the
scheduled operation.
Cautions
40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powli bu200xr2

Table of Contents