Venting Kits - Kenmore 110.77102310 Installation Instructions Manual

27" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

Venting
Kits
For more information,
call
1-800-901-2042,
or visit us at
www.applJanceaccessaries.com.
In Canada,
call
1-800-807-6777
or visit us at www.whirlpoolparts.ca.
Part
Description
Number
8171587RP
0-5"
Metal
vent periscope
4396037RP
0"-18"
Metal
vent periscope
4396011RP
18"-29"
Metal
vent periscope
4396014
29"-50"
Metal
vent periscope
4392892
in-Wail
metal
DuraVent
TM
Periscope
279818
4-way
vent kit - white
W10470674
4-way
vent kit - universal
grey
4396028
Sure Connect
TM
venting
kit
(over-the-top
installation)
4396009RP
5' Universal
connect
vent, flexible
dryer venting
4396010RP
6' SecureConnect
TM
vent° flexible
dryer
venting
4396013RB
Dryer vent installer's kit
4396033RP
5' Flexible
dryer venting
with clamps
4396727RP
8' Flexible
dryer venting
with
clamps
4396004
Dryer offset
elbow
4396005
Wall
offset
elbow
4396006RW
DuraSafe
TM
close elbow
4396007RW
Through-the-wall
vent cap
4396008RP
4" Steel dryer venting
clamps
- 2 pack
8212662
Flush mounting
Iouvered vent hood 4"
Special provisions for mobile
home installations:
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home structure
and must not terminate
beneath
the mobile
home. Terminate
the exhaust
vent outside.
Determine
vent path:
[]
Select
route that will provide
straightest
and most direct
path
outdoors.
[]
Han installation
to use fewest
number
of elbows
and turns.
[]
When
using elbows
or making
turns, allow as much room
as possible.
[]
Bend vent gradually
to avoid
kinking.
[]
Use as few 90 ° turns as possible.
Determine
vent length and elbows needed for best
drying performance:
[]
Use following
"Vent System Chart"
to determine
type of vent
material
and hood combinations
acceptable
to use.
NOTE:
Do not use vent runs longer
than
those specified
in "Vent
System Chart."
Exhaust systems longer
than those
specified
will:
[]
Shorten
life of dryer.
[]
Reduce performance,
resulting
in longer
drying
times
and increased
energy
usage.
The "Vent System Chart"
provides
venting
requirements
that wiil
help achieve
best drying
performance.
Number
of
90 ° turns
or elbows
0
1
2
3
4
Vent S
Type
of vent
RigldmetoJ
RigldmetoJ
RigldmetoJ
RigldmetoJ
RigldmetoJ
rstem Chart
j Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE:
Side and bottom
exhaust installations
have a 90 ° turn
inside the dryer. To determine
maximum
exhaust
length,
add
one 90 ° turn to the chart.
15